Hi,
few weeks ago i struggle over the same problem.
I got the tip to add the keywords
SCF=NoVarACC INT=FineGrid
which work in ca. 90% of all cases (using B3LYP).
The first is not fully known to me (didn't find the keyword in the
g92 manual), but i think it enhance the accuracy of the integrals
or is related to this point, the second point results in better
numerics while integration. Don't take it for good, i'm just a
starter...
If this doesn't work, then a slight alteration of the geometry helps
sometime (nearly in all remaining cases).
Bernhard Eck