From chemistry-request@ccl.net Fri Feb  6 14:48:50 2004
Received: from antivirus3.its.rochester.edu (antivirus3.its.rochester.edu [128.151.57.51])
	by server.ccl.net (8.12.8/8.12.8) with ESMTP id i16JmoU6021002
	for <chemistry!at!ccl.net>; Fri, 6 Feb 2004 14:48:50 -0500
Received: from antivirus3.its.rochester.edu (localhost [127.0.0.1])
	by antivirus3.its.rochester.edu (8.12.10/8.12.4) with ESMTP id i16Jqsjf011494
	for <chemistry!at!ccl.net>; Fri, 6 Feb 2004 14:52:54 -0500 (EST)
Received: from mail.rochester.edu (mail1.ats.rochester.edu [128.151.224.31])
	by antivirus3.its.rochester.edu (8.12.10/8.12.4) with SMTP id i16JqswB011489
	for <chemistry!at!ccl.net>; Fri, 6 Feb 2004 14:52:54 -0500 (EST)
Received: from mail.rochester.edu (mail.rochester.edu [128.151.224.17])
	by mail.rochester.edu (8.12.10/8.12.1) with SMTP id i16JpGUE007183
	for <chemistry!at!ccl.net>; Fri, 6 Feb 2004 14:51:16 -0500 (EST)
Sender: weiz!at!mail.rochester.edu
From: "weiz" <weiz!at!mail.rochester.edu>
Reply-to: weiz!at!mail.rochester.edu
To: chemistry!at!ccl.net
Subject: about using different methods to calculate the frequency in GAUSSIAN
X-Mailer: Quality Web Email v3.0q, http://netwinsite.com/refw.htm
Date: Fri, 06 Feb 2004 14:51:16 -0500
Priority: normal
Message-id: <4023f034.1c0e.16053!at!mail.rochester.edu>
X-Spam-Status: No, hits=0.0 required=7.0 tests=none autolearn=no version=2.61
X-Spam-Checker-Version: SpamAssassin 2.61 (1.212.2.1-2003-12-09-exp) on 
	servernd.ccl.net

Hi all:

I need to calculate the frequency of a hydrogen bonded dimer,when I used
the DFT method,the frequency is overestimated,are there any method which
can give a good evaluation for the frequency? what about the MP2?

Wei


From chemistry-request@ccl.net Fri Feb  6 14:42:39 2004
Received: from smtp3.es.uci.edu (smtp3.es.uci.edu [128.200.80.6])
	by server.ccl.net (8.12.8/8.12.8) with ESMTP id i16JgcU6020813
	for <chemistry=at=ccl.net>; Fri, 6 Feb 2004 14:42:39 -0500
Received: from muk1 (mukvisitor2.ps.uci.edu [128.200.11.127])
	by smtp3.es.uci.edu (8.12.8/8.12.8) with SMTP id i16Jiwqb026133
	for <chemistry=at=ccl.net>; Fri, 6 Feb 2004 11:44:59 -0800
Message-Id: <200402061944.i16Jiwqb026133=at=smtp3.es.uci.edu>
Date: Fri, 6 Feb 2004 11:49:27 -0800
From: "wei zhuang" <weiz=at=mail.rochester.edu>
To: "chemistry" <chemistry=at=ccl.net>
Subject: help about gaussian
X-mailer: Foxmail 5.0 [cn]
Mime-Version: 1.0
Content-Type: text/plain;
	charset="gb2312"
X-NACS_ES-MailScanner: No viruses found
X-Spam-Status: No, hits=1.1 required=7.0 tests=MIME_BASE64_TEXT autolearn=no 
	version=2.61
X-Spam-Level: *
X-Spam-Checker-Version: SpamAssassin 2.61 (1.212.2.1-2003-12-09-exp) on 
	servernd.ccl.net
Content-Transfer-Encoding: 8bit
X-MIME-Autoconverted: from base64 to 8bit by server.ccl.net id i16JgdU6020817

Hi,All:

I want to do a geometry optimization and frequency calculation of a small organic molecule surrounded by a distribution of partial charges.I get this configuration from a MD simulation using charmm. and the partial charges are actually used to represent the effect of the solvent to the molecule.

now I have to decide how to choose the partial charges,the simplest way of course,is to the partial charges from the charmm force field directly.can anyone give me a comment about what is the problem of it, and also,what are other possible way to determine to partial charges?

thank you very much.
 				

!!!!!!!!!!!!!!!!wei zhuang
!!!!!!!!!!!!!!!!weiz=at=mail.rochester.edu
!!!!!!!!!!!!!!!!!!!!2004-02-06



