Subject: Database of thermodynamic properties of organic compounds
Message-ID: <Pine.GSO.4.10.10305101646000.25880-100000@hkusua>
MIME-Version: 1.0
Content-Type: TEXT/PLAIN; charset=US-ASCII
X-MailScanner: 0

Dear CCLers,

I am seeking for databases reporting experimental data of gibbs free
energy of organic molecules. Besides, the accuracy of the data is the
major concern of my project. Do anyone know there exists some database
reporting the gibbs free energy together with the accuracy of data(in
terms of error bar)?

Thanks a lot.

Best Regards
Larry



From chemistry-request@server.ccl.net Fri May  9 13:59:04 2003
Received: from mailserver.tc.cornell.edu ([128.84.5.43])
	by server.ccl.net (8.11.6/8.11.0) with ESMTP id h49Hx4t02379
	for <chemistry@ccl.net>; Fri, 9 May 2003 13:59:04 -0400
Received: from CLOWNFISH (clownfish.tc.cornell.edu [128.84.30.88])
	by mailserver.tc.cornell.edu (Build 103 8.9.3p2/NT-8.9.3) with SMTP id NAA14999
	for <chemistry@ccl.net>; Fri, 09 May 2003 13:59:04 -0400
Message-ID: <010901c31654$ae346880$581e5480@tc.cornell.edu>
From: "Jaroslaw Pillardy" <jp86@cornell.edu>
To: <chemistry@ccl.net>
References: <200305091522.h49FMbC1211595@ds10.itodys.jussieu.fr>
Subject: New MOIL release (MOIL9)
Date: Fri, 9 May 2003 13:59:04 -0400
MIME-Version: 1.0
Content-Type: text/plain;
	charset="iso-8859-1"
Content-Transfer-Encoding: 7bit
X-Priority: 3
X-MSMail-Priority: Normal
X-Mailer: Microsoft Outlook Express 6.00.2800.1158
X-MIMEOLE: Produced By Microsoft MimeOLE V6.00.2800.1165

New MOIL release (MOIL9) http://cbsu.tc.cornell.edu/software/moil

MOIL is a molecular dynamics package that performs energy related
calculations. In addition to the common applications of energy,
minimization, dynamics, and free energy differences of biological
molecules, MOIL has a number of unique features developed in the group
of Ron Elber. Below we highlight a few of them

 - Long time dynamics algorithms - the stochastic difference equation.
Our recent methodology to extend significantly the time scale of
simulations. Serial and parallel code is now available in the sdel
module.

-  Windows 2000 graphic user interface, cmoil graphic display program,
and serial and parallel code for Windows clusters. The current version
includes a graphic interface for Windows 2000 environment, and a
molecular display program cmoil  (Windows 2000 again) .

-  Locally Enhanced Sampling.Moil includes options to perform LES 
(Locally Enhanced Sampling) simulations.

- The new code also includes implementation of the AMBER99 force field
for proteins and DNA (in addition to AMBER/OPLS extended atom
model) and a generalized Born model.

Cheers,

Jarek

------------------------------------------------------------------------
Jaroslaw Pillardy
Cornell University  -  Cornell Theory Center
616 Rhodes Hall, Ithaca, NY  14853
e-mail: jp86@cornell.edu  jarekp@tc.cornell.edu
phone: (607)-254-6333  fax: (607)-254-8888
------------------------------------------------------------------------


From chemistry-request@server.ccl.net Sat May 10 00:36:29 2003
Received: from [195.229.145.1] ([195.229.145.1])
	by server.ccl.net (8.11.6/8.11.0) with SMTP id h4A4aRt10570
	for <CHEMISTRY@ccl.net>; Sat, 10 May 2003 00:36:28 -0400
Received: from no.name.available by [195.229.145.1]
          via smtpd (for server.ccl.net [192.153.40.39]) with SMTP; Sat, 10 May 2003 08:27:43 +0400
Received: from FSD1G1D (gwd1b1h.zu.ac.ae [10.10.0.23])
	by macsmtp.zu.ac.ae (8.12.5/8.12.5) with ESMTP id h4A4Ln5k031546
	for <CHEMISTRY@ccl.net>; Sat, 10 May 2003 08:21:51 +0400
Received: from EMBADOMAIN-MTA by FSD1G1D
	with Novell_GroupWise; Sat, 10 May 2003 08:34:32 +0400
Message-Id: <sebcb998.017@FSD1G1D>
X-Mailer: Novell GroupWise Internet Agent 6.0
Date: Sat, 10 May 2003 08:33:58 +0400
From: "Iman Boukhobza" <Iman_boukhobza@zu.ac.ae>
To: <CHEMISTRY@ccl.net>, <william.wei@utoronto.ca>
Subject: Re: CCL:Cartesian convert to Z-matrix?
Mime-Version: 1.0
Content-Type: text/plain; charset=US-ASCII
Content-Disposition: inline
Content-Transfer-Encoding: 8bit
X-MIME-Autoconverted: from quoted-printable to 8bit by server.ccl.net id h4A4aTt10571

Dear William

Winmopac, vega are good in this regard and there are free version on the net

Good luck with the conversion

Iman

>>> "William Wei" <william.wei@utoronto.ca> 05/07/03 11:57PM >>>
Dear CCLers,

Does anyone know a free software can convert Cartesian coordinates to
Z-matrix? Thanks.

Have a good day!

William

-------------------------
William Wei
Faculty of Pharmacy
19 Russell Street
Toronto, ON. M5S 2S2
Tel: 1-416-946-8469
Fax: 1-416-978-8511
Email: william@phm.utoronto.ca 
       william.wei@utoronto.ca 
http://phm.utoronto.ca/~william 




-= This is automatically added to each message by mailing script =-
CHEMISTRY@ccl.net -- To Everybody  | CHEMISTRY-REQUEST@ccl.net -- To Admins
Ftp: ftp.ccl.net  |  WWW: http://www.ccl.net/chemistry/   | Jan: jkl@ccl.net 








From chemistry-request@server.ccl.net Sat May 10 09:47:39 2003
Received: from exasp.biogeo.uw.edu.pl ([212.87.8.1])
	by server.ccl.net (8.11.6/8.11.0) with ESMTP id h4ADlct29887
	for <chemistry@ccl.net>; Sat, 10 May 2003 09:47:39 -0400
Received: from localhost (localhost.localdomain [127.0.0.1])
	by exasp.biogeo.uw.edu.pl (Postfix) with ESMTP id 3501015E84
	for <chemistry@ccl.net>; Sat, 10 May 2003 15:47:45 +0200 (CEST)
Received: by exasp.biogeo.uw.edu.pl (Postfix, from userid 526)
	id 5EA4F15E7F; Sat, 10 May 2003 15:47:43 +0200 (CEST)
Date: Sat, 10 May 2003 15:47:43 +0200
From: Grzegorz Bakalarski <grzesb@biogeo.uw.edu.pl>
To: chemistry@ccl.net
Subject: Re: CCL:AIM keyword in G03
Message-ID: <20030510134743.GA27001@exasp.biogeo.uw.edu.pl>
References: <010301c31587$f338f3b0$da00000a@LAQUICOM02>
Mime-Version: 1.0
Content-Type: text/plain; charset=us-ascii
Content-Disposition: inline
In-Reply-To: <010301c31587$f338f3b0$da00000a@LAQUICOM02>
User-Agent: Mutt/1.4i
X-Virus-Scanned: by AMaViS snapshot-20020300

On Thu, May 08, 2003 at 11:33:32AM -0600, Dr. Daniel Glossman-Mitnik wrote:
> 
> Has the AIM keyword been released in G03 ?
> It is possible to do an AIM charge analysis ?
> --------------------------------------------------------------------------------

Hmm, good question... !

According to User's Reference I've got a week ago, there is no such
keyword (or any trace in index).
According to source code:

dummy-links.F:      Call GauErr('AIM not available.')

... but I can find parts of code similar to g98 routines  doing AIM ...
Maybe this is "under re-construction" at the moment????

GB