From chemistry-request@ccl.net Tue Oct 26 00:43:47 2004
Received: from halifax.ks.uiuc.edu (halifax.ks.uiuc.edu [130.126.120.36])
	by server.ccl.net (8.12.8/8.12.8) with ESMTP id i9Q5hkll014522
	for <chemistry/at/ccl.net>; Tue, 26 Oct 2004 00:43:46 -0500
Received: from maputo.ks.uiuc.edu (maputo.ks.uiuc.edu [130.126.120.159])
	by halifax.ks.uiuc.edu (8.12.10/8.12.10) with ESMTP id i9Q5uBxl024127
	(version=TLSv1/SSLv3 cipher=DHE-RSA-AES256-SHA bits=256 verify=NOT)
	for <chemistry/at/ccl.net>; Tue, 26 Oct 2004 00:56:19 -0500 (CDT)
Date: Tue, 26 Oct 2004 00:56:08 -0500 (CDT)
From: deyulu <deyulu/at/ks.uiuc.edu>
To: chemistry/at/ccl.net
Subject: CCL:Gaussian Quadruple output question
In-Reply-To: <5.2.1.1.0.20041007115435.034b58b0/at/pop.mater.unimib.it>
Message-ID: <Pine.LNX.4.61.0410260047000.13260/at/maputo.ks.uiuc.edu>
References: <5.2.1.1.0.20041007115435.034b58b0/at/pop.mater.unimib.it>
MIME-Version: 1.0
Content-Type: TEXT/PLAIN; charset=US-ASCII; format=flowed
X-Spam-Status: No, hits=0.0 required=7.5 tests=none autolearn=no version=2.61
X-Spam-Checker-Version: SpamAssassin 2.61 (1.212.2.1-2003-12-09-exp) on 
	servernd.ccl.net

Dear CCLers;
 	I have a question about Gaussian 03 Quadruple output.
I have a neutral molecule carrying zero dipole. After a single 
point calculation, Gaussain outputs a Quadrupole moment and a Traceless 
Quadrupole moment. I used the input coordinates and Mulliken atomic 
charges to calculate the the Traceless Quadrupole moment, but they don't 
agree with the numbers in the output. Depending on the system, the two 
could be different by a factor of 2.
 	Do you know whether Guassian uses Mulliken charges to calculate
dipole and quadruple? What may cause such a difference?

 	Thanks
 	Deyu

**************************************************************

Deyu Lu

Tel:     217-367-7102(h), 217-244-8946(O)
Office:  3111, Beckman Institute, UIUC
Address: 2118 S. Orchard St., Apt. 203, Urbana, IL, 61801

**************************************************************


From chemistry-request@ccl.net Tue Oct 26 07:39:44 2004
Received: from webmail.mta.ca (postal.mta.ca [138.73.1.51])
	by server.ccl.net (8.12.8/8.12.8) with ESMTP id i9QCdg5k001249
	for <chemistry-.at.-server.ccl.net>; Tue, 26 Oct 2004 07:39:43 -0500
Received: from nobody by webmail.mta.ca with local (Exim 4.20)
	id 1CMQrD-00044V-25
	for chemistry-.at.-server.ccl.net; Tue, 26 Oct 2004 09:55:23 -0300
Received: from 138.73.24.157 ( [138.73.24.157])
	as user khunter-.at.-mailserv.mta.ca by webmail.mta.ca with HTTP;
	Tue, 26 Oct 2004 09:55:23 -0300
Message-ID: <1098795323.417e493b09813-.at.-webmail.mta.ca>
Date: Tue, 26 Oct 2004 09:55:23 -0300
From: khunter-.at.-mta.ca
To: chemistry-.at.-server.ccl.net
Subject: CCL : request feedback about Lnk1e error
MIME-Version: 1.0
Content-Type: text/plain; charset=ISO-8859-1
Content-Transfer-Encoding: 8bit
X-Originating-IP: 138.73.24.157
X-Spam-Status: No, hits=1.0 required=7.5 tests=NO_REAL_NAME autolearn=no 
	version=2.61
X-Spam-Checker-Version: SpamAssassin 2.61 (1.212.2.1-2003-12-09-exp) on 
	servernd.ccl.net

Single point calculation on cytosine dimer using the Basis Set of aug-cc-pvtz 
was performed using MP2 and the gen keyword for the basis set. 

A warning of : 

Warning:  off-atom basis functions, so minimal bfn integration tests in XC 
quadrature. 

This warning was followed by:

Spurious integrated density or basis function: 
NE=   58 NElCor=    0 El error=7.74D-06 rel=1.33D-07 Tolerance=1.00D-03
 Shell    57     absolute error=9.54D-01              Tolerance=no limit
 Shell    85       signed error=4.79D-01              Tolerance=1.00D-01
 Inaccurate quadrature in CalDSu.
 Error termination via Lnk1e in /programs/g03/Rev_c02/g03/l401.exe 

Any advice as to the cause and solution to this error is greatly appreaciate.

Ken Hunter
Mount Allison University
khunter-.at.-mta.ca

From chemistry-request@ccl.net Tue Oct 26 08:43:32 2004
Received: from poincare.ciril.fr (medecine.uhp-nancy.fr [194.214.217.19])
	by server.ccl.net (8.12.8/8.12.8) with ESMTP id i9QDhV5k005027
	for <chemistry_at_server.ccl.net>; Tue, 26 Oct 2004 08:43:32 -0500
Received: from cbt.uhp-nancy.fr (host5.lctn.uhp-nancy.fr [193.50.239.5])
	(authenticated bits=0)
	by poincare.ciril.fr (8.13.1/8.13.1/Guy-23-06-2004) with ESMTP id i9QDtaL1005897
	(version=TLSv1/SSLv3 cipher=EXP1024-RC4-SHA bits=56 verify=NOT);
	Tue, 26 Oct 2004 15:55:36 +0200 (METDST)
Sender: moreau_at_poincare.ciril.fr
Message-ID: <417E5670.40909FFC_at_cbt.uhp-nancy.fr>
Date: Tue, 26 Oct 2004 15:51:45 +0200
From: Yohann Moreau <yohann.moreau_at_cbt.uhp-nancy.fr>
Organization: Equipe de Chimie et Biochimie =?iso-8859-1?Q?Th=E9oriques?=
X-Mailer: Mozilla 4.7iC-CCK-MCD  [en_US] (X11; I; AIX 4.3)
X-Accept-Language: fr, en
MIME-Version: 1.0
To: khunter_at_mta.ca
CC: chemistry_at_server.ccl.net
Subject: Re: CCL:CCL : request feedback about Lnk1e error
References: <1098795323.417e493b09813_at_webmail.mta.ca>
Content-Type: multipart/alternative;
 boundary="------------D2DA34DB4994027CA2BA66C5"
X-Spam-Score: -2.323 () BAYES_00,HTML_MESSAGE,J_CHICKENPOX_31,J_CHICKENPOX_33,J_CHICKENPOX_54,J_CHICKENPOX_92,TW_BF
X-Scanned-By: poincare.ciril.fr


--------------D2DA34DB4994027CA2BA66C5
Content-Type: text/plain; charset=iso-8859-1
Content-Transfer-Encoding: 8bit

Hello,

This  error is, as far as I know, due to a failure in determining the guess wave
function (in link 401). I've already had a similar
problem with the Harris functional guess which is the default in G03.
I'm not sure it is the solution, but you can try another method to determine the
guess (typically INDO, the default in G98)
by using the option : guess=indo  (other  are available, like EHT).

Hope this helps,

Yohann


khunter_at_mta.ca wrote:

> Single point calculation on cytosine dimer using the Basis Set of aug-cc-pvtz
> was performed using MP2 and the gen keyword for the basis set.
>
> A warning of :
>
> Warning:  off-atom basis functions, so minimal bfn integration tests in XC
> quadrature.
>
> This warning was followed by:
>
> Spurious integrated density or basis function:
> NE=   58 NElCor=    0 El error=7.74D-06 rel=1.33D-07 Tolerance=1.00D-03
>  Shell    57     absolute error=9.54D-01              Tolerance=no limit
>  Shell    85       signed error=4.79D-01              Tolerance=1.00D-01
>  Inaccurate quadrature in CalDSu.
>  Error termination via Lnk1e in /programs/g03/Rev_c02/g03/l401.exe
>
> Any advice as to the cause and solution to this error is greatly appreaciate.
>
> Ken Hunter
> Mount Allison University
> khunter_at_mta.ca
>
> -= This is automatically added to each message by the mailing script =-
> To send e-mail to subscribers of CCL put the string CCL: on your Subject: line
> and send your message to:  CHEMISTRY_at_ccl.net
>
> Send your subscription/unsubscription requests to: CHEMISTRY-REQUEST_at_ccl.net
> HOME Page: http://www.ccl.net   | Jobs Page: http://www.ccl.net/jobs
>
> If your mail is bouncing from CCL.NET domain send it to the maintainer:
> Jan Labanowski,  jlabanow_at_nd.edu (read about it on CCL Home Page)
> -+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+

--

               Yohann MOREAU, Doctorant
       Equipe de Chimie et Biochimie Thioriques
               UMR CNRS-UHP 7565 "SRMSC"
          BP 239, F-54506 Vandoeuvre-lhs-Nancy
http://www.lctn.uhp-nancy.fr/Etudiants/Yohann.Moreau.html



--------------D2DA34DB4994027CA2BA66C5
Content-Type: text/html; charset=us-ascii
Content-Transfer-Encoding: 7bit

<!doctype html public "-//w3c//dtd html 4.0 transitional//en">
<html>
Hello,
<p>This&nbsp; error is, as far as I know, due to a failure in determining
the guess wave function (in link 401). I've already had a similar
<br>problem with the Harris functional guess which is the default in G03.
<br>I'm not sure it is the solution, but you can try another method to
determine the guess (typically INDO, the default in G98)
<br>by using the option : guess=indo&nbsp; (other&nbsp; are available,
like EHT).
<p>Hope this helps,
<p>Yohann
<br>&nbsp;
<p>khunter_at_mta.ca wrote:
<blockquote TYPE=CITE>Single point calculation on cytosine dimer using
the Basis Set of aug-cc-pvtz
<br>was performed using MP2 and the gen keyword for the basis set.
<p>A warning of :
<p>Warning:&nbsp; off-atom basis functions, so minimal bfn integration
tests in XC
<br>quadrature.
<p>This warning was followed by:
<p>Spurious integrated density or basis function:
<br>NE=&nbsp;&nbsp; 58 NElCor=&nbsp;&nbsp;&nbsp; 0 El error=7.74D-06 rel=1.33D-07
Tolerance=1.00D-03
<br>&nbsp;Shell&nbsp;&nbsp;&nbsp; 57&nbsp;&nbsp;&nbsp;&nbsp; absolute error=9.54D-01&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;
Tolerance=no limit
<br>&nbsp;Shell&nbsp;&nbsp;&nbsp; 85&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;
signed error=4.79D-01&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;
Tolerance=1.00D-01
<br>&nbsp;Inaccurate quadrature in CalDSu.
<br>&nbsp;Error termination via Lnk1e in /programs/g03/Rev_c02/g03/l401.exe
<p>Any advice as to the cause and solution to this error is greatly appreaciate.
<p>Ken Hunter
<br>Mount Allison University
<br>khunter_at_mta.ca
<p>-= This is automatically added to each message by the mailing script
=-
<br>To send e-mail to subscribers of CCL put the string CCL: on your Subject:
line
<br>and send your message to:&nbsp; CHEMISTRY_at_ccl.net
<p>Send your subscription/unsubscription requests to: CHEMISTRY-REQUEST_at_ccl.net
<br>HOME Page: <a href="http://www.ccl.net">http://www.ccl.net</a>&nbsp;&nbsp;
| Jobs Page: <a href="http://www.ccl.net/jobs">http://www.ccl.net/jobs</a>
<p>If your mail is bouncing from CCL.NET domain send it to the maintainer:
<br>Jan Labanowski,&nbsp; jlabanow_at_nd.edu (read about it on CCL Home Page)
<br>-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+</blockquote>

<pre>--&nbsp;

&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Yohann MOREAU, Doctorant&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;
&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Equipe de Chimie et Biochimie Th&eacute;oriques&nbsp;&nbsp;&nbsp;
&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; UMR CNRS-UHP 7565 "SRMSC"&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;
&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; BP 239, F-54506 Vandoeuvre-l&egrave;s-Nancy&nbsp;&nbsp;
<A HREF="http://www.lctn.uhp-nancy.fr/Etudiants/Yohann.Moreau.html">http://www.lctn.uhp-nancy.fr/Etudiants/Yohann.Moreau.html</A></pre>
&nbsp;</html>

--------------D2DA34DB4994027CA2BA66C5--



From chemistry-request@ccl.net Mon Oct 25 17:29:46 2004
Received: from hotmail.com (bay10-f48.bay10.hotmail.com [64.4.37.48])
	by server.ccl.net (8.12.8/8.12.8) with ESMTP id i9PMTjll029473
	for <chemistry/at/ccl.net>; Mon, 25 Oct 2004 17:29:45 -0500
Received: from mail pickup service by hotmail.com with Microsoft SMTPSVC;
	 Mon, 25 Oct 2004 15:42:11 -0700
Received: from 199.106.16.3 by by10fd.bay10.hotmail.msn.com with HTTP;
	Mon, 25 Oct 2004 22:41:06 GMT
X-Originating-IP: [199.106.16.3]
X-Originating-Email: [tomc1234/at/hotmail.com]
X-Sender: tomc1234/at/hotmail.com
From: "Tom Cao" <tomc1234/at/hotmail.com>
To: chemistry/at/ccl.net
Subject: Choice of Force field and charge
Date: Mon, 25 Oct 2004 15:41:06 -0700
Mime-Version: 1.0
Content-Type: text/plain; format=flowed
Message-ID: <BAY10-F48rWjAKYVpMm000012f7/at/hotmail.com>
X-OriginalArrivalTime: 25 Oct 2004 22:42:11.0669 (UTC) FILETIME=[DDEA7850:01C4BAE3]
X-Spam-Status: No, hits=1.5 required=7.5 tests=FROM_ENDS_IN_NUMS autolearn=no 
	version=2.61
X-Spam-Checker-Version: SpamAssassin 2.61 (1.212.2.1-2003-12-09-exp) on 
	servernd.ccl.net

Dear All,

I have another question about the choice of force field or charge for the
study systems. I found there are multiple choice of force fields when I want
to make some calculations, could you please tell me some general rule, which
force field is better for which system? (for example, marcomolecules, small
molecules ...).

What's about the choice of charges for different systems?

Thanks a lot for your help

Sincerely

Tom

_________________________________________________________________
FREE pop-up blocking with the new MSN Toolbar   get it now! 
http://toolbar.msn.click-url.com/go/onm00200415ave/direct/01/



From chemistry-request@ccl.net Tue Oct 26 10:06:51 2004
Received: from mserv.itpa.lt (mserv.itpa.lt [193.219.53.20])
	by server.ccl.net (8.12.8/8.12.8) with ESMTP id i9QF6oG9009018
	for <CHEMISTRY/at/ccl.net>; Tue, 26 Oct 2004 10:06:50 -0500
Received: from mserv.itpa.lt (localhost [127.0.0.1])
	by mserv.itpa.lt (8.12.11/8.12.11) with ESMTP id i9QFJNXE037814;
	Tue, 26 Oct 2004 18:19:24 +0300 (EEST)
	(envelope-from tamulis$at$mserv.itpa.lt)
Received: from localhost (tamulis@localhost)
	by mserv.itpa.lt (8.12.11/8.12.11/Submit) with ESMTP id i9QFJNaj037811;
	Tue, 26 Oct 2004 18:19:23 +0300 (EEST)
	(envelope-from tamulis$at$mserv.itpa.lt)
Date: Tue, 26 Oct 2004 18:19:23 +0300 (EEST)
From: Arvydas Tamulis <tamulis$at$mserv.itpa.lt>
To: help$at$gaussian.com
cc: CHEMISTRY$at$ccl.net, Jelena Tamuliene <gicevic$at$mserv.itpa.lt>
Subject: Optimization in transition state
Message-ID: <20041026181205.Y34460$at$mserv.itpa.lt>
MIME-Version: 1.0
Content-Type: TEXT/PLAIN; charset=US-ASCII; format=flowed
X-Spam-Status: No, hits=0.0 required=7.5 tests=none autolearn=no version=2.61
X-Spam-Checker-Version: SpamAssassin 2.61 (1.212.2.1-2003-12-09-exp) on 
	servernd.ccl.net

Dear Colleagues,

Would you please to help me because received unexpected stop during 
optimization in transition state of biological derivatives applying Gaussian03.
The input line is follows:

#P B3LYP 6-31G Opt=(TS,ModRedundant) IOp(6/3=12) DIIS SCFCYC=120

The optimization started, but after one cycle stopped:

Optimization stopped.
     -- Wrong number of Negative eigenvalues: Desired=  1 Actual=  0
     -- Flag reset to prevent archiving.

My question is: what does it means these comments in G03 and how to avoid 
this stopping?

Best regards, Arvydas Tamulis


From chemistry-request@ccl.net Tue Oct 26 13:49:29 2004
Received: from mailserv.unb.ca (mailserv.unb.ca [131.202.3.23])
	by server.ccl.net (8.12.8/8.12.8) with ESMTP id i9QInSG9020157
	for <chemistry^at^ccl.net>; Tue, 26 Oct 2004 13:49:28 -0500
Received: from gollum.unb.ca (gollum.unb.ca [131.202.3.51])
	by mailserv.unb.ca (8.13.1/8.13.1) with ESMTP id i9QJ1gNK030042;
	Tue, 26 Oct 2004 16:01:42 -0300
Received: from gollum.unb.ca (localhost.localdomain [127.0.0.1])
	by gollum.unb.ca (8.12.11/8.12.8) with ESMTP id i9QJ1edg024205;
	Tue, 26 Oct 2004 16:01:40 -0300
Received: (from apache@localhost)
	by gollum.unb.ca (8.12.11/8.12.8/Submit) id i9QJ1en4024203;
	Tue, 26 Oct 2004 16:01:40 -0300
Received: from imac1.chem.unb.ca (imac1.chem.unb.ca [131.202.174.199]) 
	by webmail.unb.ca (IMP) with HTTP 
	for <s808o@127.0.0.1>; Tue, 26 Oct 2004 16:01:40 -0300
Message-ID: <1098817300.417e9f14b23dd^at^webmail.unb.ca>
Date: Tue, 26 Oct 2004 16:01:40 -0300
From: Joe Harriman <s808o^at^unb.ca>
Reply-to: j.harriman^at^unb.ca
To: Tom Cao <tomc1234^at^hotmail.com>
Cc: chemistry^at^ccl.net
Subject: Re: CCL:Choice of Force field and charge
References: <BAY10-F48rWjAKYVpMm000012f7^at^hotmail.com>
In-Reply-To: <BAY10-F48rWjAKYVpMm000012f7^at^hotmail.com>
MIME-Version: 1.0
Content-Type: text/plain; charset=ISO-8859-1
Content-Transfer-Encoding: 8bit
User-Agent: Internet Messaging Program (IMP) 3.2.2
X-Originating-IP: 131.202.174.199
X-UNB-MailScanner-Information: Please contact the ISP for more information
X-UNB-VirusScanner: Found to be clean
X-UNB-SpamDetails: 
X-MailScanner-From: s808o^at^unb.ca
X-Spam-Status: No, hits=1.5 required=7.5 tests=MAILTO_TO_SPAM_ADDR 
	autolearn=no version=2.61
X-Spam-Checker-Version: SpamAssassin 2.61 (1.212.2.1-2003-12-09-exp) on 
	servernd.ccl.net

Hi Tom,

With regards to your question concerning force fields and charge sets it is largely
dependant on the size of the systems you wish to study.  There are many varieties of
forcefields available...each with it's own distinct advantages.  Generally, the rule of
thumb is that if you are studying small systems you can use a general force field
(MMFF94, MM3, etc...).  However, if you are studying large molecules (proteins for
example) you would choose to use a specific forcefield (for example the Kollman series
of forcefields for proteins that is implemented in AMBER).  With respect to charge
models, the best partial charges come from ab initio derived calculations.  We have
found that RESP charges are highly accurate.  However, due to the nature of the
high-level calculation these are not necessarily practical.  You may want to look at
models like AM1-BCC which require only a semi-empirical calculation followed by a
charge correction.  The advantage is that it is much faster and is somewhat similar to
RESP charges.  Finally, there are many other alternatives to calculate charges quickly
like PEOE, mulliken, and Gasteiger methods.  Hopefully this helps with your question.

-Joe Harriman

Quoting Tom Cao <tomc1234^at^hotmail.com>:

> Dear All,
> 
> I have another question about the choice of force field or charge for the
> study systems. I found there are multiple choice of force fields when I want
> to make some calculations, could you please tell me some general rule, which
> force field is better for which system? (for example, marcomolecules, small
> molecules ...).
> 
> What's about the choice of charges for different systems?
> 
> Thanks a lot for your help
> 
> Sincerely
> 
> Tom
> 
> _________________________________________________________________
> FREE pop-up blocking with the new MSN Toolbar   get it now! 
> http://toolbar.msn.click-url.com/go/onm00200415ave/direct/01/
> 
> 
> 
> -= This is automatically added to each message by the mailing script =-
> To send e-mail to subscribers of CCL put the string CCL: on your Subject: line
> and send your message to:  CHEMISTRY^at^ccl.net
> 
> Send your subscription/unsubscription requests to: CHEMISTRY-REQUEST^at^ccl.net 
> HOME Page: http://www.ccl.net   | Jobs Page: http://www.ccl.net/jobs 
> 
> If your mail is bouncing from CCL.NET domain send it to the maintainer:
> Jan Labanowski,  jlabanow^at^nd.edu (read about it on CCL Home Page)
> -+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
> 
> 
> 
> 
> 
> 


From chemistry-request@ccl.net Tue Oct 26 17:13:39 2004
Received: from mail.uvigo.es (mail.uvigo.es [193.146.32.69])
	by server.ccl.net (8.12.8/8.12.8) with ESMTP id i9QMDbG9030243
	for <CHEMISTRY.-at-.ccl.net>; Tue, 26 Oct 2004 17:13:38 -0500
Received: from [128.101.96.9] (rioja.chem.umn.edu [128.101.96.9])
	(authenticated bits=0)
	by mail.uvigo.es (8.12.11/8.12.1) with ESMTP id i9QMQ6kW013759
	(version=TLSv1/SSLv3 cipher=EDH-RSA-DES-CBC3-SHA bits=168 verify=NOT);
	Wed, 27 Oct 2004 00:26:09 +0200
Subject: Re: CCL:Optimization in transition state
From: Olalla Nieto Faza <faza.-at-.uvigo.es>
To: Arvydas Tamulis <tamulis.-at-.mserv.itpa.lt>
Cc: help.-at-.gaussian.com, CHEMISTRY.-at-.ccl.net,
   Jelena Tamuliene <gicevic.-at-.mserv.itpa.lt>
In-Reply-To: <20041026181205.Y34460.-at-.mserv.itpa.lt>
References: <20041026181205.Y34460.-at-.mserv.itpa.lt>
Content-Type: text/plain
Organization: Universidade de Vigo
Message-Id: <1098829565.11352.10.camel.-at-.rioja.chem.umn.edu>
Mime-Version: 1.0
X-Mailer: Ximian Evolution 1.4.6 (1.4.6-2) 
Date: Tue, 26 Oct 2004 17:26:05 -0500
Content-Transfer-Encoding: 7bit
X-Virus-Scanned: ""
X-Spam-Status: No, hits=0.0 required=7.5 tests=none autolearn=no version=2.61
X-Spam-Checker-Version: SpamAssassin 2.61 (1.212.2.1-2003-12-09-exp) on 
	servernd.ccl.net

Just try to use  "opt=(ts,noeigen, modredundant)"
in your command line. 
What is happening is that the optimization algorithm checks the
curvature of the hessian at each step, and tells the program to die if 
the number of negative eigenvalues is not the expected (one, in this
case). When you use this keyword, the program will continue the
optimization even if it finds no negative eigenvalue or more than one.

In the gaussian manual (have a look at
http://www.gaussian.com/g_ur/k_opt.htm ) they say it is not advisable to
disregard this test, but I have been successfully using the "noeigen"
keyword by default in my ts optimizations for quite a while (otherwise,
unless you have very good initial guesses, you are often going to find
this error message and see your calculations die in the first
optimization steps).

Regards,

Olalla



On Tue, 2004-10-26 at 10:19, Arvydas Tamulis wrote:
> Dear Colleagues,
> 
> Would you please to help me because received unexpected stop during 
> optimization in transition state of biological derivatives applying Gaussian03.
> The input line is follows:
> 
> #P B3LYP 6-31G Opt=(TS,ModRedundant) IOp(6/3=12) DIIS SCFCYC=120
> 
> The optimization started, but after one cycle stopped:
> 
> Optimization stopped.
>      -- Wrong number of Negative eigenvalues: Desired=  1 Actual=  0
>      -- Flag reset to prevent archiving.
> 
> My question is: what does it means these comments in G03 and how to avoid 
> this stopping?
> 
> Best regards, Arvydas Tamulis
> 
> 
> -= This is automatically added to each message by the mailing script =-
> To send e-mail to subscribers of CCL put the string CCL: on your Subject: line
> and send your message to:  CHEMISTRY.-at-.ccl.net
> 
> Send your subscription/unsubscription requests to: CHEMISTRY-REQUEST.-at-.ccl.net 
> HOME Page: http://www.ccl.net   | Jobs Page: http://www.ccl.net/jobs
> 
> If your mail is bouncing from CCL.NET domain send it to the maintainer:
> Jan Labanowski,  jlabanow.-at-.nd.edu (read about it on CCL Home Page)
> -+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
> 
> 
> 
> 
-- 

________________________________________________________________________________
Olalla Nieto Faza                              Ph: (+34) 986-813721
Graduate Student                               e-mail: faza.-at-.uvigo.es 
Dpto. Quimica Organica                         http://webs.uvigo.es/faza
Universidade de Vigo                           
Lagoas-Marcosende 36200
Vigo (Spain)