Hi netters,
I do geometry optimization with Gaussian92 and run almost after every
optimization step in the following error:

   ERROR ON Z-MATRIX CARD NUMBER    7
   ANGLE Alpha IS OUTSIDE THE VALID RANGE OF 0 TO 180.

What should I do to get out of this dilemma. Should I
1) fix this angle until all other coordinates are optimized or
2) correct it in the following manner and start a new optimization:

           d
          /    old angle(b-c-d) = oa
     b - c     old torsion(a-b-c-d) = ot
    /
   a           new angle = 360-oa = na
               new torsion = -ot
 
In this way I have "mirrored" the regarded coordinate at the a,b,c-plane (not
really because of different angle oa and na).

Any help is appriciated.
#
#+----------------------------------------------+
#| Hagen Dufner                                 |
#| Technische Hochschule Darmstadt              |
#| Physikalische Chemie I                       |
#| Petersenstr. 20                              |
#| 64287 Darmstadt, Germany                     |
#| Phone: (+int) 6151 165397                    |
#| Fax:   (+int) 6151 164298                    |
#| Network : <dufner@pc.chemie.th-darmstadt.de> |
#+----------------------------------------------+


From GREULACH@pcmail.uni-trier.de  Wed Jun  8 09:24:27 1994
Received: from apollo11.Uni-Trier.De  for GREULACH@pcmail.uni-trier.de
	by www.ccl.net (8.6.4/930601.1506) id IAA09230; Wed, 8 Jun 1994 08:51:10 -0400
Received: from servrz02.uni-trier.de by apollo11.Uni-Trier.De (5.65/2.00)
	id AA01201; Wed, 8 Jun 94 14:50:52 +0200
Received: From NETWARESERVER/WORKQUEUE by servrz02.uni-trier.de
          via Charon-4.0-VROOM with IPX id 100.940608145040.352;
          08 Jun 94 14:50:55 -200
Message-Id: <MAILQUEUE-101.940608145036.544@pcmail.uni-trier.de>
To: chemistry@ccl.net
From: "GREULACH UWE"  <GREULACH@pcmail.uni-trier.de>
Organization: University of Trier
Date:         8 Jun 94 14:50:36 GMT+2
Subject:      Amplifier and potentiostat for microelectrodes
Priority: normal
X-Mailer:     Pegasus Mail v2.3 (R5).


Hi netters,
I'm still searching for an amplifier (pico- or femtoammeter)
(and if it is possible) in conjunction with a potentiostat for
voltammetry with a Pt- microdisk electrode. It should be possible to
measure in the area of femtoamp currents and to registrate cyclic
voltammograms by using high scan rates. The electrochemical
experiments will be done with a three-electrode system from Metrohm.
Does anybody know something about such instruments from EG&G, BAS,
ERC, Radiometer or anything else???

Thank you very much for your answers and please send them to

Greulach@pcmail.uni-tier.de

Bye and all the best, Hansi Nirmaier






From ghislain@jupiter.sun.csd.unb.ca  Wed Jun  8 09:32:07 1994
Received: from unb.ca  for ghislain@jupiter.sun.csd.unb.ca
	by www.ccl.net (8.6.4/930601.1506) id IAA09006; Wed, 8 Jun 1994 08:25:03 -0400
Received: from jupiter.sun.csd.unb.ca by unb.ca (4.1/SMI-4.1-940224-08:05)
	id AA15470; Wed, 8 Jun 94 09:25:01 ADT
Received: from [131.202.47.1] by jupiter.sun.csd.unb.ca (4.1/SMI-4.1-940126-11:10)
	id AA18925; Wed, 8 Jun 94 09:24:59 ADT
Date: Wed, 8 Jun 94 09:24:58 ADT
Message-Id: <9406081224.AA18925@jupiter.sun.csd.unb.ca>
Mime-Version: 1.0
Content-Type: text/plain; charset="us-ascii"
To: CHEMISTRY@ccl.net
From: ghislain@jupiter.sun.csd.unb.ca (Ghislain Deslongchamps)
Subject: Sun SCSI disk on Indigo = OK


Dear Netters,
     Thank you for all the useful responses despite my ill-placed posting.
I really appreciate your help.

     I was able to get the Sun SCSI disk to work fine on my SGI Indigo.  It
turned out to be simple once I entrenched myself in the man pages and
followed your advice:  I simply reformatted the disk (fx -x "dksc(0,5)"
i.e. it's on SCSI controller 0, SCSI address 5), then I made a filesystem
and mounted it (Add_disk 5).  Et voila!
     The SGI disk (1Gb internal 3.5" fast SCSI) was $4400 canadian. The Sun
disk (1.05Gb external SCSI) was $1320 !!!

Gratefully Yours,

Ghis    :-)


+++++++++++++++++++++++++++++++++++++++++++++++++++++
+    Ghislain Deslongchamps,  Assistant Professor   +
+    Department of Chemistry                        +
+    University of New Brunswick                    +
+    Fredericton, N.B.  CANADA  E3B 5A3             +
+    e-mail:  GHISLAIN@UNB.CA                       +
+    phone:   506-453-4795 (or 453-4792)            +
+    FAX:     506-453-4599                          +
+++++++++++++++++++++++++++++++++++++++++++++++++++++



From xiang@auriga.rose.brandeis.edu  Wed Jun  8 11:24:21 1994
Received: from auriga.rose.brandeis.edu  for xiang@auriga.rose.brandeis.edu
	by www.ccl.net (8.6.4/930601.1506) id KAA11127; Wed, 8 Jun 1994 10:56:51 -0400
Received: by auriga.rose.brandeis.edu (5.57/Ultrix3.0-C)
	id AA00715; Wed, 8 Jun 94 10:59:01 -0400
Date: Wed, 8 Jun 94 10:59:01 -0400
From: xiang@auriga.rose.brandeis.edu (Xiaoou Xiang)
Message-Id: <9406081459.AA00715@auriga.rose.brandeis.edu>
To: chemistry@ccl.net
Subject: Monte Carlo


Dear Netters:

Could any of you tell me where to obtain Monte Carlo simulation programs for 
molecular mechanics calculations?

Phil Xiang
Biophysics program
Brandeis University

From PA13808%UTKVM1.BITNET@phem3.acs.ohio-state.edu  Wed Jun  8 11:29:08 1994
Received: from phem3  for PA13808%UTKVM1.BITNET@phem3.acs.ohio-state.edu
	by www.ccl.net (8.6.4/930601.1506) id LAA11245; Wed, 8 Jun 1994 11:03:16 -0400
From: <PA13808%UTKVM1.BITNET@phem3.acs.ohio-state.edu>
Received: from UTKVM1.BITNET (MAILER@UTKVM1) by phem3.acs.ohio-state.edu (PMDF
 V4.2-13 #5888) id <01HDAPKW0AQO99PKKU@phem3.acs.ohio-state.edu>; Wed,
 8 Jun 1994 11:02:58 EDT
Received: from UTKVM1 (PA13808) by UTKVM1.BITNET (Mailer R2.10 ptf000) with
 BSMTP id 5737; Wed, 08 Jun 94 11:02:11 LCL
Date: Wed, 08 Jun 94 10:40:27 LCL
Subject: G92 LICENSING PROBLEM
To: netters <chemistry@ccl.net>
Message-id: <01HDAPKW0AQQ99PKKU@phem3.acs.ohio-state.edu>
Content-transfer-encoding: 7BIT


  I am at a large state university(U of TENN). The admin has  policy of support
ing a central comp center rather helping faculty to purchase individual
 work stations. In order to satisfy the needs of a number of faculty who
  need ab initio calc as PART of their research prog I have been trying to
 replace G90 by G92 on an IBM 3090 at the central comp center. The UT lawyers
 and The Gaussian lawyers have not been able to come to an agreement
  concerning the licensing. The problem seems to concern any legal
  problem which might arise out of the use of G92 !!!! would under TENN
  law have to be fought according to the laws here whereas G. is incorporated i
  in Illinois. I have heard that other UNIV have had similar problems. I would
  like to here from anyone who has had this problem particularly if they
  have been able to solve it. Our position has become desperate  because
  we need calc of geom and freq at at least the MP2 level and it is in these
  areas that G92 is much superior to G90.
        I would also like to here about other prog which are capable of doing
   MP2 or CCD geom opt and freq calc as efficiently or more so than G92
   which are easily available for a SUN or IBM/6000 work stn
          The future of several grad students and at least one professor
    depends on getting this problem resolved speedily !!!!
              John E. Bloor(PA13808 at utkvm1.bitnet or utkvm1.utk.edu
               or phone 615-573-5176)

From xiang@auriga.rose.brandeis.edu  Wed Jun  8 14:24:39 1994
Received: from auriga.rose.brandeis.edu  for xiang@auriga.rose.brandeis.edu
	by www.ccl.net (8.6.4/930601.1506) id OAA15871; Wed, 8 Jun 1994 14:11:17 -0400
Received: by auriga.rose.brandeis.edu (5.57/Ultrix3.0-C)
	id AA01487; Wed, 8 Jun 94 14:13:22 -0400
Date: Wed, 8 Jun 94 14:13:22 -0400
From: xiang@auriga.rose.brandeis.edu (Xiaoou Xiang)
Message-Id: <9406081813.AA01487@auriga.rose.brandeis.edu>
To: chemistry@ccl.net
Subject: Monte Carlo,again...


Dear Max and other Netters:

I posted this question earlier:

>>Could any of you tell me where to obtain Monte Carlo simulation programs for 
>>molecular mechanics calculations?

Let me be more specific. I want to use Monte Carlo method to sample the 
conformational space of a small drug molecule to find the global and local
minima. The molecular mechanics programs I have are AMBER and CHARMM, none of
which came with Monte Carlo utility.

Phil Xiang
Biophysics program
Brandeis University

From shenkin@still3.chem.columbia.edu  Wed Jun  8 15:24:39 1994
Received: from still3.chem.columbia.edu  for shenkin@still3.chem.columbia.edu
	by www.ccl.net (8.6.4/930601.1506) id OAA16704; Wed, 8 Jun 1994 14:52:30 -0400
Received: by still3.chem.columbia.edu (931110.SGI/930416.SGI.AUTO)
	for chemistry@ccl.net id AA05904; Wed, 8 Jun 94 14:52:18 -0400
From: "Peter Shenkin" <shenkin@still3.chem.columbia.edu>
Message-Id: <9406081452.ZM5902@still3.chem.columbia.edu>
Date: Wed, 8 Jun 1994 14:52:07 -0400
In-Reply-To: xiang@auriga.rose.brandeis.edu (Xiaoou Xiang)
        "CCL:Monte Carlo,again..." (Jun  8,  2:13pm)
References: <9406081813.AA01487@auriga.rose.brandeis.edu>
X-Mailer: Z-Mail (3.1.0 22feb94 MediaMail)
To: xiang@auriga.rose.brandeis.edu (Xiaoou Xiang), chemistry@ccl.net
Subject: Re: CCL:Monte Carlo,again...
Content-Type: text/plain; charset=us-ascii
Mime-Version: 1.0


On Jun 8,  2:13pm, Xiaoou Xiang wrote:
> Subject: CCL:Monte Carlo,again...
> >>Could any of you tell me where to obtain Monte Carlo simulation programs
> >> for
> >>molecular mechanics calculations?
>
> Let me be more specific. I want to use Monte Carlo method to sample the
> conformational space of a small drug molecule to find the global and local
> minima. The molecular mechanics programs I have are AMBER and CHARMM, none
> of
> which came with Monte Carlo utility.

Phil,

BatchMin/MacroModel supports Monte Carlo conformational search, as well
as MD and minimization, in the context of AMBER*, MM2*, MM3* or OPLSA*
force-fields.  It should be well suited to your application.

The cost to academics is quite low.

For more info:
	finger mmod@still3.chem.columbia.edu
and send me email if you have questions.

Caveat:  I work on the program, so I'm prejudiced in its favor.

	-P.



-- 
********** After the revolution, everyone will have a home page... **********
Peter S. Shenkin, Box 768 Havemeyer Hall, Dept. of Chemistry, Columbia Univ.,
New York, NY  10027;     shenkin@still3.chem.columbia.edu;     (212) 854-5143
***** (... but the Internet will be too busy for anyone to access it.) ******


From CHAKRAVO@ucs.indiana.edu  Wed Jun  8 20:24:31 1994
Received: from PO3.indiana.edu  for CHAKRAVO@ucs.indiana.edu
	by www.ccl.net (8.6.4/930601.1506) id TAA19796; Wed, 8 Jun 1994 19:30:47 -0400
Message-Id: <199406082330.TAA19796@www.ccl.net>
Received: from LOCAL:.prism.DECnet by PO3.Indiana.EDU; id AA13031
	(5.65c+jsm/2.5.1jsm); Wed, 8 Jun 1994 18:24:31 -0500
Date: Wed, 8 Jun 94 18:30:47 EST
From: Subhas Chakravorty <CHAKRAVO@ucs.indiana.edu>
X-To: PO%"chemistry@ccl.net"
Subject: MOPAC
To: chemistry@ccl.net


Which is the mos recent version MOPAC93, MOPAC7 , MOPAC6
perhaps there is an ftp site where I can read about these versions.
I intend to email the entire MOPAC to a friend in India. 
Please email me the info . I thank you in advance
Subhas Chakravorty
PS: ALL my gopher searches landed up with sites for MOPAC6.
    So I am wondering if thats the current one! which is free software
    but copyrighted.

From SBOESCH@aardvark.ucs.uoknor.edu  Wed Jun  8 21:24:27 1994
Received: from aardvark.ucs.uoknor.edu  for SBOESCH@aardvark.ucs.uoknor.edu
	by www.ccl.net (8.6.4/930601.1506) id VAA20325; Wed, 8 Jun 1994 21:21:15 -0400
From: <SBOESCH@aardvark.ucs.uoknor.edu>
Message-Id: <199406090121.VAA20325@www.ccl.net>
Date: Wed, 8 Jun 94 20:21 CDT
Subject: NQS problem
To: chemistry@ccl.net
X-VMS-To: IN%"chemistry@ccl.net"


	Dear Netters,

	This message is directed to those who use NQS on an IBM RISC/6000.
	The other day we had an rather odd occurence.  One of our
	users was running two different jobs in differenct queues ( one
	was an amber job, the other a gaussian job).  At appoximately
	the same time both his jobs were ejected from the queue, but 
	they continued to run.
	The *.batch-log files appeared in his directories, but they
	contained no information as to why the jobs were ejected from
	the queue.
	Although we have not been running NQS very long, the experience
	we do have suggests that a job will not be ejected from the
	queue unless the job either finished successfully or terminates
	abnormally.
	The first thought that comes to mind is that the jobs exceeded
	the time limit in their respective queues, however, that was
	not the case.
	The amber job had run approximately 4 hours and it was in a 24
	hour queue and the gaussian job was being run in an unlimited
	time   queue.
	If anyone has experienced this before or has any suggestions
	I would be most appreciative.

	Thanks very much.

	SBOESCH@aardvark.ucs.uoknor.edu

	S.E. Boesch
	Department of Chemistry & Biochemistry
	University of Oklahoma
	Norman, Oklahoma