From D.Winkler@chem.csiro.au  Thu Jul  7 21:51:16 1994
Received: from auric.chem.csiro.au  for D.Winkler@chem.csiro.au
	by www.ccl.net (8.6.9/930601.1506) id VAA22302; Thu, 7 Jul 1994 21:43:39 -0400
Received: from chem.csiro.au ([138.194.40.143]) by auric.chem.csiro.au with SMTP id AA09751
  (5.67b/IDA-1.5 for chemistry@ccl.net); Fri, 8 Jul 1994 11:42:19 +1000
Date: Fri, 8 Jul 94 11:44:48 EST
From: "Dr. Dave Winkler" <D.Winkler@chem.csiro.au>
Subject: Announcement:  MGS meeting for 1995
To: chminf-l@iubvm.ucs.indiana.edu, chemistry@ccl.net
Cc: inoue@greencross.co.jp
X-Mailer: LeeMail 2.0.4
Message-Id: <AA42ECB1@chem.csiro.au>



                      P R E L I M I N A R Y   N O T I C E

              INTERNATIONAL MOLECULAR GRAPHICS SOCIETY MEETING 1995

                    The MGS 95 meeting will be held from: 

                         27 August - 1 September 1995
 
                 Daydream Island, near the Great Barrier Reef, 
                             Queensland Australia.

This meeting will also involve the Royal Australian Chemical Institute (RACI) 
Division of Medicinal and Agricultural Chemistry.  The meeting will cover all 
aspects of molecular design.  The venue is a resort island in the Whitsundays 
and offers a full range of facilities.  The program will be organized like 
Gordon conferences with morning and evening sessions, allowing time for 
interaction during the afternoons.

Further information on registration, program, costs etc will be posted in the 
near future.  Information can be obtained from myself or other members of the 
organizing committee:

Prof Peter Andrews, Chairman (p.andrews@mailbox.uq.oz.au)
Ruth Drinkwater, University of Queensland, (R.Drinkwater@mailbox.uq.oz.au)

Northern hemisphere representatives are:

           Dr. Bob Langridge, UCSF (North America)
           Dr. Mike Hann, Glaxo UK, (Europe)
           Prof. Akiko Itai, University of Tokyo (Asia)

Cheers,

Dave
__________________________________________________________________________

   Dr. David A. Winkler                        Voice: 61-3-542-2244      
   Principal Research Scientist                Fax:   61-3-543-8160      
   CSIRO Division of Chemicals and Polymers
   Private Bag 10       
   Clayton, Australia.

   "Life is what happens to you while you're making other plans"


From jmeehan@cc.utas.edu.au  Fri Jul  8 06:51:55 1994
Received: from corinna.its.utas.edu.au  for jmeehan@cc.utas.edu.au
	by www.ccl.net (8.6.9/930601.1506) id CAA23344; Fri, 8 Jul 1994 02:58:05 -0400
Received: from tasman.cc.utas.edu.au by corinna.its.utas.edu.au with SMTP id AA07521
  (5.67a/IDA-1.5 for <chemistry@ccl.net>); Fri, 8 Jul 1994 16:58:46 +1000
Date: Fri, 8 Jul 1994 16:50:40 +1000 (EST)
From: John Meehan <jmeehan@cc.utas.edu.au>
Subject: problem with ANALYT in Mopac7
To: chemistry@ccl.net
Message-Id: <Pine.3.03.9407081640.A2489-a100000@tasman.cc.utas.edu.au>
Mime-Version: 1.0
Content-Type: TEXT/PLAIN; charset=US-ASCII


G'day everyone,

I've been looking at mopac7 recently and have a problem. 

The problem is that I have discovered a problem when I specify ANALYT. I
get a recurring error
sqrt: DOMAIN error
sqrt: DOMAIN error
over and over again!!!! Does anyone know what the problem is and/or have a
fix for it. 

sqrt ONLY occurs in ef.f in the source code.

Any ideas?????
Cheers 
John


----------------------------------------------
John Meehan                   O     CH2-COOH      
Department of Biochemistr     "    /
University of Tasmania,    HO-P-O-C-COOH
Austral                       |    \
                             HO     CH2-COOH
PHOSPHOCITRIC ACID ----    A powerful, natural 
   inhibitor of Pathological Biomineralization
----------------------------------------------


From herbert.homeier@rchs1.chemie.uni-regensburg.de  Fri Jul  8 09:51:34 1994
Received: from comsun.rz.uni-regensburg.de  for herbert.homeier@rchs1.chemie.uni-regensburg.de
	by www.ccl.net (8.6.9/930601.1506) id JAA27148; Fri, 8 Jul 1994 09:26:56 -0400
Received: from rchs1.chemie.uni-regensburg.de by comsun.rz.uni-regensburg.de with SMTP id AA20737
  (5.65c/IDA-1.4.4 for <CHEMISTRY@ccl.net>); Fri, 8 Jul 1994 15:27:48 +0200
Received: by rchs1.chemie.uni-regensburg.de (4.1/URRZ-sub (1.5))
	id AA07751; Fri, 8 Jul 94 15:25:03 +0200
Date: Fri, 8 Jul 94 15:25:03 +0200
From: Herbert Homeier (t4720) <Herbert.Homeier@chemie.uni-regensburg.de>
Message-Id: <9407081325.AA07751@rchs1.chemie.uni-regensburg.de>
To: CHEMISTRY@ccl.net
Subject: GACS (Guide to Available Chemistry Software) Project ?
Reply-To: na.hhomeier@na-net.ornl.gov


Hello all,

There a many places where archives for chemistry software
are under current development. But still, software for a
given problem is often difficult to find.

In my opinion, there is a need for a Guide to Available
Chemistry Software (GACS) Project. It should be similar in 
spirit to the Guide to Available Mathematical Software 
(GAMS) project. This is a database structured by problem
classes and subclasses. The database contains the pointer to
a place where the software can be obtained. GAMS is available 
under gopher or WWW as
#
Type=1
Name=GAMS (Guide to Available Mathematical Software project)
Path=
Host=gams.nist.gov
Port=70
URL: http//gams.nist.gov
#
and offers a telnet and an X11 user interface.

Maybe that some features of a GACS
are already implemented or under construction.

My question is whether anybody knows of any GACS-like 
project or plans for it. If there is some interest group
for such a project, please let me know. 

Perhaps it is not too much effort to get a GACS started.
It might be possible to get interface and database software 
>from the GAMS people. Then, some people have to decide on a
class/subclass structure of common chemical problems for
which software is available or desirable. The most laborious
part would be to enter the data per software module. But
this could perhaps be done in some "automated" fashion or
by each software provider for his/her software.

What do you think about this? In case of suffient response
I will summarize to CCL.

Best regards

Herbert

--------------------------------------------------------------
Dr. Herbert H. H. Homeier
Institut fuer Physikalische und Theoretische Chemie
Universitaet Regensburg
D-93040 Regensburg, Germany
Phone: +49-941-943 4720                FAX  : +49-941-943 2305
email: na.hhomeier@na-net.ornl.gov
--------------------------------------------------------------


From CUNDARIT@MSUVX1.MEMPHIS.EDU  Fri Jul  8 11:51:41 1994
Received: from msuvx1.memphis.edu  for CUNDARIT@MSUVX1.MEMPHIS.EDU
	by www.ccl.net (8.6.9/930601.1506) id LAA28850; Fri, 8 Jul 1994 11:49:08 -0400
From: <CUNDARIT@MSUVX1.MEMPHIS.EDU>
Received: from MSUVX1.MEMPHIS.EDU by MSUVX1.MEMPHIS.EDU (PMDF V4.3-8 #5958)
 id <01HEGLQHB56EA3J8HD@MSUVX1.MEMPHIS.EDU>; Fri,
 08 Jul 1994 10:50:21 -0500 (CDT)
Date: Fri, 08 Jul 1994 10:50:21 -0500 (CDT)
Subject: Solid State Extended Huckel Program
To: chemistry@ccl.net
Message-id: <01HEGLQHB56GA3J8HD@MSUVX1.MEMPHIS.EDU>
X-VMS-To: IN%"chemistry@ccl.net"
MIME-version: 1.0
Content-type: TEXT/PLAIN; CHARSET=US-ASCII
Content-transfer-encoding: 7BIT


Hi,

	A colleague of mine wanted to know about the availability
of a solid state extended Huckel program.  I recall something on the
net a few weeks ago, but did not take note of it.
	Is this program available from QCPE and, if so, can it
be gotten by ftp?
	Thanks.

Tom
------------------------------------------------------------------------------
Thomas R. Cundari                         Address until the end of August
Asst. Professor of Chemistry              Tom Cundari
Computational Inorganic Chemistry Lab     Visiting Scientist
University of Memphis                     CST-3, C346
Memphis, TN 38152                         Los Alamos National Lab
phone: 901-678-2629                       Los Alamos, NM 87545
fax:   901-678-3447                       
e-mail: cundarit@memstvx1.memst.edu
http://www.memst.edu/chemistry/umchem.html
-------------------------------------------------------------------------------

From arsoftwa@clark.net  Fri Jul  8 12:51:37 1994
Received: from clark.net  for arsoftwa@clark.net
	by www.ccl.net (8.6.9/930601.1506) id LAA28962; Fri, 8 Jul 1994 11:57:33 -0400
Received: (from arsoftwa@localhost) by clark.net (8.6.9/8.6.9) id LAA12057; Fri, 8 Jul 1994 11:58:30 -0400
Date: Fri, 8 Jul 1994 11:58:30 -0400 (EDT)
From: Welcome to ARSoftware <arsoftwa@clark.net>
Subject: ANNOUNCE HSC Chemistry V2 Now Available
To: chemistry@ccl.net
Message-ID: <Pine.3.89.9407081106.A11554-0100000@explorer>
MIME-Version: 1.0
Content-Type: TEXT/PLAIN; charset=US-ASCII



HSC Chemistry for Windows Version 2.0 Now Available

Contact: George West - west@arsoftware.arclch.com (800) 257-0073, (301) 
459-3773 - Browser available, open URL http://arsoftware.arclch.com

LANDOVER, MD -- ARSoftware HSC Chemistry for Windows Version 2.0, a 
chemical reaction and equilibrium software application is now available.  
Version 2.0 offers many new features that make HSC faster, more powerful, and 
a lot more versatile.  The new version is 2 to 4 times faster (depending on 
application), contains 1000 new organic compounds, an improved Gibbs 
program, and more.  A few of HSC Version 2.0's features:    (reviews to follow 
shortly)

Over 2000 additional compounds (over 1000 are organic) -  User-defined 
database expanded to 3000 compounds - Equilibrium calculations performed as 
functions of pressure, temperature, and amount - Read and write Solgasmix files 
- Reactants and product amounts can be defined in moles, grams, and liters - 
Upgraded phase stability diagram - Quick and easy importing and exporting of 
ASCII files to and from the main and user-defined databases - User-defined 
database can be read to Microsoft Excel as a text file for editing and returned to 
HSC.

HSC has a wide range of application possibilities in industry, research, and 
education.  All calculations will automatically access an integrated 
thermochemical database that now includes more than 8000 compounds.  

System requirements:  MS Windows 3 or later.  Minimum hardware:  386SX-
based PC, 2MB RAM, hard disk, EGA card and mouse. 

From EWING@jcvaxa.jcu.edu  Fri Jul  8 13:51:38 1994
Received: from jcvaxa  for EWING@jcvaxa.jcu.edu
	by www.ccl.net (8.6.9/930601.1506) id NAA01064; Fri, 8 Jul 1994 13:37:33 -0400
Received: from jcvaxa.jcu.edu by jcvaxa.jcu.edu (PMDF V4.3-7 #6158)
 id <01HEGRS231WG8WWHFF@jcvaxa.jcu.edu>; Fri, 8 Jul 1994 13:39:58 EST
Date: Fri, 08 Jul 1994 13:39:58 -0500 (EST)
From: "DAVID W. EWING (216) 397-4742" <EWING@jcvaxa.jcu.edu>
Subject: Question on enforcing symmetry in MOPAC93
To: chemistry@ccl.net
Message-id: <01HEGRS27VIA8WWHFF@jcvaxa.jcu.edu>
X-VMS-To: IN%"chemistry@ccl.net"
X-VMS-Cc: EWING
MIME-version: 1.0
Content-type: TEXT/PLAIN; CHARSET=US-ASCII
Content-transfer-encoding: 7BIT


MOPAC93 Users:

We cannot seem to enforce symmetry in some of our optimizations.  Sample 
input and output are given below.  Any suggestions?  Thank you in advance 
for any thoughts anyone may have on this!

Dave Ewing
John Carroll University
ewing@jcvaxa.jcu.edu

--------------------------------------------------------------
MNDO SYMMETRY EF
DI PERFLUORO METHYL ETHER

O
C  1.4  1
C  1.4  0  130  1            1 2
F  1.3  1  110  1   60  0  2 1 3
F  1.3  0  110  0  180  0  2 1 3
F  1.3  0  110  0  300  0  2 1 3
F  1.3  0  110  0   60  0  3 1 2
F  1.3  0  110  0  180  0  3 1 2 
F  1.3  0  110  0  300  0  3 1 2
0  0.0  0    0  0    0  0  0 0 0

2, 1, 3
4, 1, 5, 6, 7, 8, 9
4, 2, 5, 6, 7, 8, 9


 *******************************************************************************
 **                            MOPAC 93 (c) Fujitsu                           **
 *******************************************************************************

                                MNDO CALCULATION RESULTS


 *******************************************************************************
 *                   MOPAC  93.00               CALC'D. Thu Jul  7 09:22:50 1994
 *  SYMMETRY - SYMMETRY CONDITIONS TO BE IMPOSED
 *   T=      - A TIME OF  3600.0 SECONDS REQUESTED
 *  DUMP=N   - RESTART FILE WRITTEN EVERY  3600.0 SECONDS
 *  EF       - USE EF ROUTINE FOR MINIMUM SEARCH
 ***********************************************************************030BY030



     PARAMETER DEPENDENCE DATA

        REFERENCE ATOM      FUNCTION NO.    DEPENDENT ATOM(S)

             DESCRIPTIONS OF THE FUNCTIONS USED

 MNDO EF SYMMETRY
 DI PERFLUORO METHYL ETHER
 

    ATOM   CHEMICAL  BOND LENGTH    BOND ANGLE     TWIST ANGLE
   NUMBER  SYMBOL    (ANGSTROMS)     (DEGREES)      (DEGREES)
    (I)                  NA:I          NB:NA:I      NC:NB:NA:I     NA   NB   NC

      1      O       
      2      C         1.40000  *                                  1
      3      C         1.40000        130.00000  *                 1    2
      4      F         1.30000  *     109.00000  *   60.00000      2    1    3
      5      F         1.30000        110.00000     180.00000      2    1    3
      6      F         1.30000        110.00000     -60.00000      2    1    3
      7      F         1.30000        110.00000      60.00000      3    1    2
      8      F         1.30000        110.00000     180.00000      3    1    2
      9      F         1.30000        110.00000     -60.00000      3    1    2


          CARTESIAN COORDINATES 

    NO.       ATOM         X         Y         Z

     1         O        0.0000    0.0000    0.0000
     2         C        1.4000    0.0000    0.0000
     3         C       -0.8999    1.0725    0.0000
     4         F        1.8232    0.6146    1.0645
     5         F        1.8446   -1.2216    0.0000
     6         F        1.8446    0.6108   -1.0579
     7         F       -0.7178    1.8057   -1.0579
     8         F       -2.1215    0.6278    0.0000
     9         F       -0.7178    1.8057    1.0579
  C: (MNDO):  M.J.S. DEWAR, W. THIEL, J. AM. CHEM. SOC., 99, 4899, (1977)       
  O: (MNDO):  M.J.S. DEWAR, W. THIEL, J. AM. CHEM. SOC., 99, 4899, (1977)       
  F: (MNDO):  M.J.S. DEWAR, H.S. RZEPA, J. AM. CHEM. SOC., 100, 777, (1978)     


      MOLECULAR POINT GROUP   :   C2v 


      RHF CALCULATION, NO. OF DOUBLY OCCUPIED LEVELS = 28


            INTERATOMIC DISTANCES
0
                  O  1       C  2       C  3       F  4       F  5       F  6
 ------------------------------------------------------------------------------
     O    1   0.000000
     C    2   1.400000   0.000000
     C    3   1.400000   2.537662   0.000000
     F    4   2.198879   1.300000   2.959442   0.000000
     F    5   2.212454   1.300000   3.577033   2.122544   0.000000
     F    6   2.212454   1.300000   2.977382   2.122544   2.115874   0.000000
     F    7   2.212454   2.977382   1.300000   3.518567   4.104839   2.827328
     F    8   2.212454   3.577033   1.300000   4.085868   4.376139   4.104839
     F    9   2.212454   2.977382   1.300000   2.806357   4.104839   3.531388
0
                  F  7       F  8       F  9
 ------------------------------------------
     F    7   0.000000
     F    8   2.115874   0.000000
     F    9   2.115874   2.115874   0.000000

          DIAGONAL MATRIX USED AS START HESSIAN

 CYCLE:   1 TIME:   1.98 TIME LEFT:   3598.0 GRAD.:   113.872 HEAT:-342.7629    
 CYCLE:   2 TIME:   1.22 TIME LEFT:   3596.8 GRAD.:    15.769 HEAT:-345.8834    
 CYCLE:   3 TIME:   1.22 TIME LEFT:   3595.6 GRAD.:     3.922 HEAT:-345.9849    
 CYCLE:   4 TIME:   1.32 TIME LEFT:   3594.3 GRAD.:     2.659 HEAT:-346.0091    
 CYCLE:   5 TIME:   1.33 TIME LEFT:   3592.9 GRAD.:     1.976 HEAT:-346.0177    
 CYCLE:   6 TIME:   1.33 TIME LEFT:   3591.6 GRAD.:     0.485 HEAT:-346.0199    

     RMS GRADIENT =  0.48517  IS LESS THAN CUTOFF =  1.00000



 -------------------------------------------------------------------------------
 MNDO EF SYMMETRY
 DI PERFLUORO METHYL ETHER
 


     GEOMETRY OPTIMISED USING EIGENVECTOR FOLLOWING (EF).     
     SCF FIELD WAS ACHIEVED                                   


                               MNDO    CALCULATION
                                                       MOPAC 93.00
                                                       Thu Jul  7 09:23:00 1994




          FINAL HEAT OF FORMATION =       -346.01988 KCAL =  -1447.74720 KJ


          TOTAL ENERGY            =      -3456.29585 EV
          ELECTRONIC ENERGY       =     -11240.10933 EV  POINT GROUP:     Cs  
          CORE-CORE REPULSION     =       7783.81348 EV

 WARNING -- GEOMETRY IS NOT AT A STATIONARY POINT
          IONIZATION POTENTIAL    =         15.29658
          NO. OF FILLED LEVELS    =         28
          MOLECULAR WEIGHT        =    154.012


          SCF CALCULATIONS  =                7
          COMPUTATION TIME =   9.152 SECONDS





    ATOM   CHEMICAL  BOND LENGTH    BOND ANGLE     TWIST ANGLE
   NUMBER  SYMBOL    (ANGSTROMS)     (DEGREES)      (DEGREES)
    (I)                  NA:I          NB:NA:I      NC:NB:NA:I     NA   NB   NC

      1      O       
      2      C         1.41239  *                                  1
      3      C         1.40000        132.06566  *                 1    2
      4      F         1.35705  *     108.94444  *   60.00000      2    1    3
      5      F         1.30000        110.00000     180.00000      2    1    3
      6      F         1.30000        110.00000     -60.00000      2    1    3
      7      F         1.30000        110.00000      60.00000      3    1    2
      8      F         1.30000        110.00000     180.00000      3    1    2
      9      F         1.30000        110.00000     -60.00000      3    1    2

From nash@chem.wisc.edu  Fri Jul  8 14:51:39 1994
Received: from fozzie.chem.wisc.edu  for nash@chem.wisc.edu
	by www.ccl.net (8.6.9/930601.1506) id OAA01788; Fri, 8 Jul 1994 14:19:11 -0400
Received: by fozzie.chem.wisc.edu;
          id AA16814; 5.57/42; Fri, 8 Jul 94 13:20:13 -0500
Message-Id: <9407081820.AA16814@fozzie.chem.wisc.edu>
X-Sender: nash@fozzie.chem.wisc.edu
Mime-Version: 1.0
Content-Type: text/plain; charset="us-ascii"
Date: Fri, 8 Jul 1994 13:20:13 -0500
To: chemistry@ccl.net
From: nash@chem.wisc.edu (John R. Nash)
Subject: G92/DFT SUMMARY: "Spurious integrated..."


Thanks to all who replied to my question about "spurious integrated
density" in G92/DFT.  As many of you noted, I have revision F, and the
problem is apparently fixed in revision G.  So, the best solution is to
update.

To summarize the work-arounds for revisions earlier than G: 'Int=FineGrid'
helps (and this is what I had done), and 'SCF=NoVarAcc' should be used as
well.  Another suggestion was to use GUESS=ALWAYS, which often helps.  The
workarounds are NOT required for revision G and higher.

I should note that in general, I am happy with G92/DFT as a convenient and
familiar implementation of this calculational method.

Thanks again for all of the timely and informative replies.

-john nash

-===-John R. Nash-==-nash@chem.wisc.edu-==-UW-Madison Chem. Dept-===-



From jmolmod@organik.uni-erlangen.de  Fri Jul  8 14:58:46 1994
Received: from faui45.informatik.uni-erlangen.de  for jmolmod@organik.uni-erlangen.de
	by www.ccl.net (8.6.9/930601.1506) id NAA01404; Fri, 8 Jul 1994 13:55:41 -0400
Received: from derioc1.organik.uni-erlangen.de by uni-erlangen.de with SMTP;
	id AA08877 (5.65c-6/7.3v-FAU); Fri, 8 Jul 1994 19:56:29 +0200
Received: by organik.uni-erlangen.de;
	id AA16870 (5.64/7.3n-FAU); Fri, 8 Jul 94 19:51:45 +0200
From: Journal of Molecular Modeling <jmolmod@organik.uni-erlangen.de>
Message-Id: <9407081751.AA16870@derioc1.organik.uni-erlangen.de>
Subject: Announce: JOURNAL OF MOLECULAR MODELING
To: chemistry@ccl.net
Date: Fri, 8 Jul 94 19:51:43 METDST
Cc: roth@organik.uni-erlangen.de (Henryette Roth)
X-Mailer: ELM [version 2.3 PL11]



		***********************************
 		*				  *
		*  Journal of Molecular Modeling  *
		*				  *
		***********************************



   Megalon S.A. will be launching a fully electronical journal, the JOURNAL OF
 MOLECULAR MODELING on the  first of  January 1995. The  JOURNAL OF  MOLECULAR
 MODELING will accept papers from all areas of molecular and materials modeling
 both applications and method  development, ranging from classical and  quantum
 mechanical  modeling,  QSAR, "de novo"  ligand design,  neural nets,  genetic 
 algorithm, expert systems, information retrieval and management etc. J.Mol.Mod.
 will be edited by Tim Clark at the University of Erlangen. 

    Tim Clark, editor, Erlangen 1994.

****   Further informations follows below   ***********************************

 The new JOURNAL OF MOLECULAR MODELING is an attempt to overcome the financial
problems associated with publishing full color illustrations conventionally at 
a resonable cost and to avoid the long publication delays often associated with
bimonthly or  quarterly conventional  journals. The  journal will accept papers
>from all areas of molecular and materials modeling, both applications and method
development. Papers will be subject to the normal peer-review system.

 It is  anticipated that the  first year's issue will  correspond to a roughly
bimonthly  conventional journal,  although, as outlined  below, the  JOURNAL OF
MOLECULAR MODELING will not  actually consist of papers  grouped together  into regular issues.
 
 Articles  published in the  journal will be  published first as  PostScript andcommon  word-processor  files  on  the  two  Megalon  FTP-servers.  Access  for
subscribers  will either be via  FTP or by  Gopher. A CD-rom  version  will be
released at the end of each year. A classical bound full color hardcopy version
will also be available at the end of each year. Subscribers will be notified of
new  papers  being  placed on the  servers by  Email and  will then be  able to
download the PostSript manuscript to their own workstation or PC, where they may
either view it with a public domain  PostScript viewer, or  print it in black or
white or color, depending on thier hardware. The servermode of publication means
that the  journal must not  adhere to a fixed  number of issues per  year, but 
rather  that the  individual  papers will become  available as  soon as they are
accepted and  proof-read. This should lead to  unprecedently short  publication
times. Papers may also be submitted electronically and as much of the refereeing
process as possible will use electronic communications.



Subscription Rates:

>  Personal Subscriptions (FTP or Gopher access, Email notification of papers)
							$ 75.- p.a.

>  Personal Subscriptions (FTP or Gopher access, Email notification of papers
   and CD-rom of the entire volume at the end of the year)
							$ 100.- p.a.

>  Library or Industrial Subscriptions (FTP or Gopher access, Email notification
   of papers and CD-rom of the entire volume at the end of the year)
							$ 200.- p.a.

>  CD-rom of past year's volumes			$ 100.- p.a.

>  Individual reprints (color) will be available after publication on a per page
  price basis. Ordering information will be published with the journal contents.

>  A bound color hardcopy of each year's volume will be available, probably from
   the Springer Verlag, Heidelberg.



^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^
^   Journal of Molecular Modeling                                              ^
^   Computer-Chemie-Centrum                                                    ^
^   Universitaet Erlangen-Nuernberg                                            ^
^   Naegelsbachstrasse 25                                                      ^
^   D-91052  Erlangen                                                          ^
^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^
^   email:	jmolmod@organik.uni-erlangen.de                                ^
^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^

From dobado@ugr.es  Fri Jul  8 15:51:40 1994
Received: from relay.rediris.es  for dobado@ugr.es
	by www.ccl.net (8.6.9/930601.1506) id PAA03085; Fri, 8 Jul 1994 15:40:54 -0400
Received: from rediris.es by relay.rediris.es (PMDF V4.2-14 #4193) id
 <01HEH8NH1GNK8WXH93@relay.rediris.es>; Fri, 8 Jul 1994 21:42:13 GMT+1
X400-Received: by mta iris-dcp in /PRMD=iris/ADMD=mensatex/C=es/; Relayed; Fri,
 8 Jul 1994 21:41:44 UTC+0100
X400-Received: by /PRMD=iris/ADMD=mensatex/C=es/; Relayed; Fri,
 8 Jul 1994 21:40:59 UTC+0200
Date: Fri,  8 Jul 1994 21:40:59 UTC+0200
From: Welcome to ARSoftware <arsoftwa@clark.net>
Subject: CCL:ANNOUNCE HSC Chemistry V2 Now Available
Sender: dobado@ugr.es
To: chemistry@ccl.net
Message-id: <Pine.3.89.9407081106.A11554-0100000@explorer>
Content-identifier: <Pine.3.89.9407081106.A11554-0100000@explorer>
Content-transfer-encoding: 7BIT
Conversion: Prohibited
X400-Content-type: P2-1984 (2)
X400-MTS-identifier: [/PRMD=iris/ADMD=mensatex/C=es/;940708214059]
X400-Originator: dobado@ugr.es
X400-Recipients: chemistry@ccl.net


>Errors-to: ccl@ccl.net
>X-Envelope-to: dobado@ugr.es, jaouad@ugr.es
>Content-type: TEXT/PLAIN; charset=US-ASCII
>MIME-Version: 1.0
>Precedence: bulk


HSC Chemistry for Windows Version 2.0 Now Available

Contact: George West - west@arsoftware.arclch.com (800) 257-0073, (301) 
459-3773 - Browser available, open URL http://arsoftware.arclch.com

LANDOVER, MD -- ARSoftware HSC Chemistry for Windows Version 2.0, a 
chemical reaction and equilibrium software application is now available.  
Version 2.0 offers many new features that make HSC faster, more powerful, and 
a lot more versatile.  The new version is 2 to 4 times faster (depending on 
application), contains 1000 new organic compounds, an improved Gibbs 
program, and more.  A few of HSC Version 2.0's features:    (reviews to follow 
shortly)

Over 2000 additional compounds (over 1000 are organic) -  User-defined 
database expanded to 3000 compounds - Equilibrium calculations performed as 
functions of pressure, temperature, and amount - Read and write Solgasmix files 
- Reactants and product amounts can be defined in moles, grams, and liters - 
Upgraded phase stability diagram - Quick and easy importing and exporting of 
ASCII files to and from the main and user-defined databases - User-defined 
database can be read to Microsoft Excel as a text file for editing and returned to 
HSC.

HSC has a wide range of application possibilities in industry, research, and 
education.  All calculations will automatically access an integrated 
thermochemical database that now includes more than 8000 compounds.  

System requirements:  MS Windows 3 or later.  Minimum hardware:  386SX-
based PC, 2MB RAM, hard disk, EGA card and mouse. 

---Administrivia: This message is automatically appended by the mail exploder:
CHEMISTRY@ccl.net -- everyone     | CHEMISTRY-REQUEST@ccl.net -- coordinator
MAILSERV@ccl.net: HELP CHEMISTRY  | Gopher: www.ccl.net 73
Anon. ftp www.ccl.net     | CHEMISTRY-SEARCH@ccl.net -- archive search
http://www.ccl.net/chemistry.html |     for info send: HELP SEARCH to MAILSERV

From arsoftwa@clark.net  Fri Jul  8 16:02:06 1994
Received: from clark.net  for arsoftwa@clark.net
	by www.ccl.net (8.6.9/930601.1506) id PAA03209; Fri, 8 Jul 1994 15:50:51 -0400
Received: (from arsoftwa@localhost) by clark.net (8.6.9/8.6.9) id PAA18287; Fri, 8 Jul 1994 15:51:52 -0400
Date: Fri, 8 Jul 1994 15:51:51 -0400 (EDT)
From: Welcome to ARSoftware <arsoftwa@clark.net>
Subject: REVIEW R&D Mag - Speed Up Your Chemistry
To: chemistry@ccl.net
Message-ID: <Pine.3.89.9407081538.A15782-0100000@explorer>
MIME-Version: 1.0
Content-Type: TEXT/PLAIN; charset=US-ASCII




(More info available on WWW, open URL:   http://arsoftware.arclch.com)

HSC Chemistry for Windows

Review in the November, 1993 issue of  R&D Magazine

The following material is copyrighted by R&D

"Speed Up Your Chemistry"

by Tim Studt


(The following review was performed on Version 1.1, Version 2.0 has many 
new enhancements and additions.)


After using it for only a few months, Judith Ulan already feels that HSC 
Chemistry for Windows could give her company the ability to patent a new 
process.

Ulan, a research chemist at Chemetics, Richmond, British Columbia, Canada, 
uses the HSC Chemistry software package to evaluate chlor-alkali equilibria 
for different material compositions and temperatures.   She then uses this 
data to evaluate bleaching processes for pulp-and-paper factories.

Outokumpu's HSC Chemistry is a PC-based system that solves chemical 
reaction and equilibrium problems by using data from various 
thermodynamic and electrochemical databases.

"You could perform these analyses by looking up tables in books, but the 
books slow you down and your mind gets tired from all the number 
crunching," says Ulan.  "HSC Chemistry lets you quickly change materials 
and operating conditions in a reaction.  Each iteration of my problems only 
take from 30 seconds to 2 minutes to solve."

Similarly, Barry Verdegan, manager of filtration research analysis at Nelson 
Industries, Stoughton, WI, uses HSC Chemistry to speed up development of 
high-performance filter systems.

"We use HSC Chemistry to evaluate how various filter materials operate at 
different
temperatures," says Verdegan.  "Tests evaluating our filters' solid-liquid 
interfaces and gas vapor effects would take about six months to perform.  It 
only takes about two weeks to perform a software analysis with HSC 
Chemistry."

HSC Chemistry has six calculation options for different types of chemical 
problems:  reaction problems, equilibrium compositions, heat and material 
balances, formula weights, phase-stability diagrams, and Eh-pH diagrams.  A 
special cell equilibrium calculation option also is available for calculating 
charge and phase composition in electrochemical cells, such as batteries.

All HSC Chemistry calculations draw upon a thermochemical data-base 
containing enthalpy, entropy, and heat capacity data for more than 5,600 
chemical compounds.  Users also can edit and save new data to this database.

Reaction equations typed into HSC Chemistry's input field result in a tabular 
display of
thermochemical data - such as heats of reaction and equilibrium constants - 
that is similar to those presented in many thermochemical data books.  The 
results, however, are displayed immediately and exactly at the temperatures 
desired.

The equilibrium compositions section of HSC Chemistry gives you the 
product amounts from a given amount of raw material at a theoretical 
equilibrium state.

"HSC is easy to use, but you really have to be careful about knowing basic 
chemical reactions," says Chemetics' Ulan.  "Occasionally, the program can 
extrapolate to show an impossible condition, which is obvious if you know 
your basics.  The software helps by giving you a warning when it is 
extrapolating."

Verdagen agrees.  "You really have to know your basics and set realistic 
boundary conditions."

"Additionally, since HSC Chemistry was developed in Finland, technical 
support questions that can't be answered by local representatives have to be 
handled through long-distance conversations," says Verdagen.

HSC Chemistry requires 386 or better PC, 2 MB RAM, and Microsoft 
Windows 3.0/3.1.  Paper copies of all calculations and diagrams can be 
printed on any Microsoft Windows-supported printer.


Available exclusively in North America from ARSoftware
for more info e-mail   west@arsoftware.arclch.com