From chemistry-request- at -server.ccl.net Tue Feb 13 05:44:14 2001 Received: from rzumail2.unizh.ch (rzumail2.unizh.ch [130.60.128.10]) by server.ccl.net (8.11.0/8.11.0) with ESMTP id f1DAiEw19083 for ; Tue, 13 Feb 2001 05:44:14 -0500 Received: from zisgi.unizh.ch (zisgi.unizh.ch [130.60.19.17]) by rzumail2.unizh.ch (8.9.3/8.9.3/08) with ESMTP id LAA18211; Tue, 13 Feb 2001 11:44:12 +0100 (MET) From: "Dr. Peter Burger" Received: [(chburger.,at,.localhost) by zisgi.unizh.ch (SGI-8.9.3/SMI-IRIX6.2/USAR_MAIL_V2) id LAA42365; Tue, 13 Feb 2001 11:44:12 +0100 (MET)] Message-Id: <200102131044.LAA42365 #at# zisgi.unizh.ch> Subject: Re: CCL:Second negative frequency To: dturner ^%at%^ syntem-sa.fr (David Turner) Date: Tue, 13 Feb 2001 11:44:12 +0100 (CET) Cc: chemistry _-at-_)ccl.net In-Reply-To: <3A88ED90.89EC1676 -x- at -x- syntem-sa.fr> from "David Turner" at Feb 13, 1 09:17:20 am X-Mailer: ELM [version 2.4 PL25 PGP2] MIME-Version: 1.0 Content-Type: text/plain; charset=US-ASCII Content-Transfer-Encoding: 7bit Good point, however, what are you going to do about it? I spent alot computer time in reoptimizing using the calculated hessian / recalculating the second derivatives (sometimes several times) and had the excact same question. I analyzed these low frequencies and in my case quite often these were just rotations of methyl groups etc. in the peripheral positions, while the larger imaginary frequency was corresponding to the TS. Anyways, this made me wonder how this is handled in publications. Are these sometimes small frequencies sometimes ignored? Will this be always mentioned in the paper, would the referees accept additional imaginary frequencies if they had been analyzed thoroughly? Sorry, for this question I do not want to blame anyone - but being originally not trained as an theoretical chemist, I am just curious. So far, I was lucky to get rid of all additional negative frequencies, by reoptimization, but considering the usual error bars of these frequencies as mentioned in the last post and the size of some of my systems (DFT on 50-130 atoms with numerical second derivatives by finite difference), I could be tempted to just mention in the paper that that there is a residual small imaginary frequency, which I cannot get rid of with reasonable computational effort, e.g. redo the force calculation a third or forth time. Any comments? Peter > Your second value (36 cm-1) could easily be positive given the error > associated with normal mode calculations (+/-50 cm-1 or so). Perhaps > you have only one imaginary frequency ...