Re: CHELPGUNIX
We have recently compiled CHELPG to run on our SGI platforms and
discovered
that we get a different answer for the water test job than the one
provided in the doc file. I believe this is a problem with Gaussian 90
on our boxes not CHELPG as we have always had problems with the STO-3G
basis set which remain unresolved. We have been able to reproduce data
from the article (J. Comput. Chem., 11, 361-373 (1990)) refernced in the
doc file. I would appreciate it if anyone who has run CHELPG with a haigher
basis set than STO-3G on a relatively small molecule would let me have your
Gausian and CHELPG output files so I can make an exact comparison.
Also I would appreciate it if anyone could point out any further
discussion
on choosing Van der Waal's exclusion radii for larger atoms ( second row and
transition metals ) for use in CHELPG.
Jim Schmidt
University of Rochester
Pharmacology Dept.
jims -8 at 8-
duce.medicine.rochester.edu
jps
In general, Gaussian 90 works fine on the SGI regardless of basis set.
Anyone who has specific problems or concerns should report them to
moses -8 at 8- gaussian.com.
Mike Frisch
Gaussian, Inc.
-------