Re: CCL:Ab-initio Force Constants



 > Ab-initio frequency calculations give
 > force constants in cartesian and internal
 > coordinates, the units being respectively
 > hartree/bohr (and not hartree/bohr**2) and
 > atomic units.
 Wrong, the unit of force constants in cartesian
 coordinates is hartree/bohr**2 (which is an atomic
 unit). The unit of force constants in internal coordinates
 depends on the types of internal coordinates involved
 in the force constant, if it is a bend-bend the unit is
 hartree/bohr**2, if it is a angle-bend the unit is
 hartree/(bohr*rad), and if it is an angle-angle the unit
 is hartree/rad**2.
 > Does somebody know how to
 > convert them in mdyn/angstrom?
 1 hartree/bohr**2 = 15.5691905 mdyn/Ang
 1 hartree/(bohr*rad) = 8.2388584 mdyn
 1 hartree/rad**2 = 4.3598149 mdyn*Ang
 Joerg-R. Hill
 -------------------------------------------------------------------------------
 -
 Dr. Joerg-Ruediger Hill   | Every attempt to employ mathematical methods in the
 Biosym Technologies, Inc. | study of chemical questions must be considered pro-
 9685 Scranton Road        | foundly irrational  and  contrary  to the spirit of
 San Diego, CA 92121-2777  | chemistry ...  If mathematical analysis should ever
 USA                       | hold a prominent place in chemistry - an aberration
                           | which  is  happily  almost  impossible  -  it would
 Phone (619) 546-5508      | occasion  a rapid  and  widespread  degeneration of
 Fax   (619) 458-0136      | that science.
 E-mail jxh()at()biosym.com     |                                      A. Comte,
 1838
 -------------------------------------------------------------------------------
 -
  The opinions expressed in this message are my personal opinions and no offical
  statements of Biosym Technologies, Inc. For informations about Biosym products
  take a look at: http://www.biosym.com/.
 -------------------------------------------------------------------------------
 -