Spartan questions summary
Hello everybody,
yesterday I posted 2 questions about Spartan. A large number of people
responded; my thanks to all of them. The original questions and summary of
replies follow.
Cheers
--
Konstantin Momot
momot' at \`iris5.chem.arizona.edu
http://aruba.ccit.arizona.edu/~momot/research.html
==========================================================================
1) "How to start a Spartan job from a non-graphical terminal ?"
The proper command is
spartan -x jobname &
One needs not worry about the Spartan path or env. variables. Do not use
sp_abinitio etc.; spartan will take care of that. jobname should be a
directory containinng files _spartan, input, and propin. They can be
created from either interactive version by setting up (but not submitting)
a job, or by a text editor if you know the proper format.
In an unlikely case when you start interactive Spartan by a command other
than spartan, you probably need to use that command instead:
interactive-spartan-alias -x jobname &
======================================================================
2) "Why PURED keyword did not work on Fe atom with 3-21G ?"
As I was told, the keyword was intended to work on diffuse functions of
main group elements, but not on d-elements. This does not apply to
STO-3G, where PURED will work with d-elements.
============================================================================