Re: CCL:G98: ONIOM and Amber on TM systems
- From: "Stefan Fau" <fau |-at-| qtp.ufl.edu>
- Subject: Re: CCL:G98: ONIOM and Amber on TM systems
- Date: Thu, 20 Jul 2000 14:21:37 -0400
Hi Valentine,
The ONIOM method requires 3 calculations for
a molecule: a low level calc of the whole molecule
(ll/all), a low level calc of the high level part (ll/part)
and a high level calc of the high level part (hl/part).
The ONIOM energy is defined as
E(ONIOM) = E(ll/all) - E(ll/part) + E(hl/part)
Although the low level energy contributions of the
high level part seem to cancel out, that is not
completely true. In order to have well behaved
high level parts, broken bonds are saturated with
hydrogen. This causes a difference in the MM
energy terms between ll/all and ll/part that reaches
at least three atoms inside the high level part
(dihedral angle with the saturation H). For that
reason (and programming reasons, I assume),
you need MM parameters for all atoms in the
molecule.
In the last few days there was a thread concerning
ONIOM energies. One of the mails pointed to an
article that explains the ONIOM method in more
detail.
Stefan
______________________________________________________________________
Dr. Stefan Fau | fau |-at-| qtp.ufl.edu
Quantum Theory Project | (352) 392-6714
University of Florida
Gainesville, FL 32611-8435