From: James Robinson <prsjjr.-at-.bath.ac.uk>
To: "Daniel R. Rohr" <rohrd.-at-.students.uni-marburg.de>, ccl <chemistry.-at-.ccl.net>
Subject: RE: Eigenvalues of hessian
Date: Wed, 28 May 2003 16:37:04 +0100
Message-ID: <NGBBILMDCLJNCGKMLPEEKEHECCAA.prsjjr.-at-.bath.ac.uk>
MIME-Version: 1.0
Content-Type: text/plain;
	charset="iso-8859-1"
X-Priority: 3 (Normal)
X-MSMail-Priority: Normal
X-Mailer: Microsoft Outlook IMO, Build 9.0.2416 (9.0.2911.0)
X-MimeOLE: Produced By Microsoft MimeOLE V6.00.2600.0000
Importance: Normal
In-Reply-To: <1054131647.16827.13.camel@charly>
X-Scanner:  *19L2yu-0006nm-6R*hmabWlK1Neg*
Content-Transfer-Encoding: 8bit
X-MIME-Autoconverted: from quoted-printable to 8bit by server.ccl.net id h4SFaogC008056

Some numerical methods use small perturbations in the x, y and z planes to compute force constants. Unfortunately this effectively contaminates the calculation with net translations. Could this be happening in your Hessian calc? 

James (if I wrong, do let me know!)

-----Original Message-----
From: Computational Chemistry List [mailto:chemistry-request.-at-.ccl.net]On
Behalf Of Daniel R. Rohr
Sent: 28 May 2003 15:21
To: ccl
Subject: CCL:Eigenvalues of hessian


Hi CCLers

 Does anybody of you know, why there are more than 3N-6 nonzero
eigenvalues of the hessian? I am especially interested in the question,
whether this error is due to the errors made by differentiation or
whether they are due to an error within the method itself. I usually get
only 3 zero eigenvalues. No matter if the hessian is calculated on a
stationary point or not.

Thanks for your help

Daniel Rohr

-- 
-----------------------------------------------------------------------
 Daniel Rohr                                    Fachbereich Chemie der
                                                Philipps-Universitdt
 Tel.: +49-6421-28-25686                        Hans-Meerwein-Stra_e
 Fax.: +49-6421-28-25566                        D-35043 Marburg
 eMail: rohrd.-at-.stud-mailer.uni-marburg.de        Germany
-----------------------------------------------------------------------




-= This is automatically added to each message by mailing script =-
To send e-mail to subscribers of CCL put the string CCL: on your Subject: line
and send your message to:  CHEMISTRY.-at-.ccl.net

Send your subscription/unsubscription requests to: CHEMISTRY-REQUEST.-at-.ccl.net 
HOME Page: http://www.ccl.net   | Jobs Page: http://www.ccl.net/jobs 

If your mail is bouncing from CCL.NET domain send it to the maintainer:
Jan Labanowski,  jkl.-at-.ccl.net (read about it on CCL Home Page)
-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+