Re: CCL:Crystal structure vs geometry optimised structure
- From: elewars <elewars/at/trentu.ca>
- Subject: Re: CCL:Crystal structure vs geometry optimised
structure
- Date: Wed, 23 Jul 2003 21:37:22 -0400
2003 July 23
Hello,
It is probably not a good idea to use experimental geometries for freq calc's,
because
freq calc's are strictly valid only at the geometry obtained by the same method
as the
freq calc. Thus a B3LYP/6-31G* freq calc should be done on a geometry obtained
by a
B3LYP/6-31G* optimization. Since your freq jobs are likely to be about as long
or longer
than any geom optimizations, you probably won't lose very much time by doing the
optimizations first.
Another problem with crystal structures is that they may differ significantly
from the
isolated molecule structures that I presume you will use for your freq jobs (you
won't
use a crystal lattice as input, I guess); but you took account of this by saying
"where
the DFT...is in excellent agreement..."
It would be interesting to do some freq calc's on both DFT-opt and experimental
structures and see how much they differ. But conventional wisdom is that the
DFT-opt
structures are the ones to use.
If you didn't want freqs, just relative energies of isomers, you could do
single-point
calculations (much faster than optimizations) on the experimental structures.
Again, it
might be interesting to compare relative energies based on the experimental and
the
DFT-opt structures.
E. Lewars
==========
noel.oboyle2/at/mail.dcu.ie wrote:
> Hello CCLers,
> I intend to carry out DFT calculations on inorganic complexes. In some
cases
> I have crystal structures available.
>
> Is it better to use crystal structures as a starting point for energy and
> frequency calculations, or to use DFT-optimised structures? (where the
DFT-optimised
> structure is in excellent agreement with the crystal structure)
>
> Thanks,
> Noel O'Boyle
> Han Vos Research Group,
> Dublin City University.
>
> -= This is automatically added to each message by mailing script =-
> To send e-mail to subscribers of CCL put the string CCL: on your Subject:
line
> and send your message to: CHEMISTRY/at/ccl.net
>
> Send your subscription/unsubscription requests to:
CHEMISTRY-REQUEST/at/ccl.net
> HOME Page: http://www.ccl.net | Jobs Page: http://www.ccl.net/jobs
>
> If your mail is bouncing from CCL.NET domain send it to the maintainer:
> Jan Labanowski, jkl/at/ccl.net (read about it on CCL Home Page)
> -+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+