CCL:RE: FlexX und SGE
- From: Holger Claußen <claussen~at~biosolveit.de>
- Subject: CCL:RE: FlexX und SGE
- Date: Thu, 2 Dec 2004 12:32:21 +0100
Hello Dirk,
we recognized that it is actually a problem to combine
FlexX and batch queuing systems (BQS) like for example
SGE, because FlexX uses PVM for parallel computing.
PVM set s up a separate control flow that conflicts
with any BQS.
Thus we developed a small tool called Distributor that
allows for setting up parallel FlexX jobs without PVM
that employs a BQS, e.g. SEG.
The Distributor is a generic tool that can be applied
to anycommand line based tool like for example FlexX.
The only requirement is that the tool takes as input
an ASCII file that contains the input for several runs
of the tool and that this file can be split by rules
(e.g. multi-mol2 ligand files for FlexX-Dockings).
The Distributor splits the input files and creates for
each batch a separate working environment and calls a
job in the BQS to process the batch. The BQS is than
responsible for the job scheduling. So there is only
one control instance.
After the jobs are done, the Distributor gathers the
ASCII output of all jobs and cats this to one output
file automatically (e.g. the predicted scores of FlexX).
In addition, the Distributor can do some basic job
statistic and report this optionally by email.
If the called tool (e.g. FlexX) is able to call a
callback script after each run, the distributor
is also able to restart failed jobs with the item
following the failed one.
The split functions can be defined by the user.
Split functions for mol2, sdf, and for splitting
ASCII files by pattern or by counting are pre defined.
The Distributor works with several BQS.
It is tested with SEG and OpenPBS.
If this sound interesting to you I would be happy
to send you more details on the Dirtsibutor.
Regards,
Holger
--
BioSolveIT GmbH - An der Ziegelei 75 - 53757 St.Augustin - Germany
Dr. Holger Clau_en claussen~at~biosolveit.de
Phone: +49-2241-2525-0 / Fax: -525 www.biosolveit.de
> -----Original Message-----
> From: Computational Chemistry List [mailto:chemistry-request~at~ccl.net] On
> Behalf Of Dirk Cla_en-Houben
> Sent: Monday, November 29, 2004 1:43 PM
> To: CCL
> Subject: CCL:FlexX und SGE
>
>
> Dear CCL readers,
>
> has anybody some experience running FlexX from BiosolvIT and Tripos on a
> queuing system with the SGE (Sun Grid Engine)? Every suggestion or
> example is welkome.
>
> Thanks in advance for your help,
> Regards,
> Dirk.
>
> Dirk Classen-Houben
> BV Biotechnologies GmbH
> (Biovertis - information-driven drug design AG)
> Campus Vienna Biocenter 6
> 1030 Vienna, Austria
>
> Phone +43-1-7989303-110
> Fax +43-1-7989303-400
> Email dirk.classen-houben' at \`biovertis.c