RE: W:isotope calculations
- From: "Shobe, David" <dshobe !!
sud-chemieinc.com>
- Subject: RE: W:isotope calculations
- Date: Wed, 15 Jun 2005 09:49:25 -0400
Your input should be something like this (i.e. what's between the two rows
of + signs):
++++++++++++++++++++++++++++++++++++++++++++++++++++++
%chk=formaldehyde
# cbs-4m
formaldehyde
0 1
c
o 1 oc2
h 1 hc3 2 hco3
h 1 hc4 2 hco4 3 dih4
oc2 1.450000
hc3 1.089000
hco3 109.471
hc4 1.089000
hco4 109.471
dih4 120.000
--link1--
%chk=formaldehyde
# cbs-4m=(readfc,readiso) geom=check guess=read
Formaldehyde, deuterated
0 1
298.16 0.0 0.0
12
16
2
2
++++++++++++++++++++++++++++++++++++++++++++++++++++++
--David Shobe, Ph.D., M.L.S.
S|d-Chemie, Inc.
phone (502) 634-7409
fax (502) 634-7724
Don't bother flaming me: I'm behind a firewall.
-----Original Message-----
From: Computational Chemistry List [mailto:chemistry-request !!
ccl.net] On Behalf Of kono, , lemke
Sent: Tuesday, June 14, 2005 7:13 PM
To: chemistry !! ccl.net
Subject: CCL:W:isotope calculations
i am running cbs-4 calculations on small deuterated organics and can not get
gaussian to rerun for heavier isotopes. does gaussian require a blank line at
the input end? any suggestion as how to edit the input below would be
appreciated. thanks kono
%chk=formaldehyde
cbs-4m
formaldehyde
0 1
c
o 1 oc2
h 1 hc3 2 hco3
h 1 hc4 2 hco4 3 dih4
oc2 1.450000
hc3 1.089000
hco3 109.471
hc4 1.089000
hco4 109.471
dih4 120.000
--link1--
%chk=formaldehyde
cbs-4m
0 1
298.16 0.0 0.0
12
16
2
2
-= This is automatically added to each message by the mailing script =-
To send e-mail to subscribers of CCL put the string CCL: on your Subject: line
and send your message to: CHEMISTRY !! ccl.net
Send your subscription/unsubscription requests to: CHEMISTRY-REQUEST !! ccl.net
HOME Page: http://www.ccl.net
| Jobs Page: http://www.ccl.net/jobs
If your is mail bouncing from ccl.net domain due to spam filters, please
use the Web based form from CCL Home Page
-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+