Hello,
I am trying to run ONIOM calculations (M06-2x/6-31G(d):AMBER) in Gaussian 09
Revision A.02 and I am having a few problems. My system has 4162 atoms, where
149 are in the QM region (1316 basis functions). I am running my calculations on
8 processors with 8GB of memory and 160 GB of disk space.
In order to build my model, there are multiple stages of calculations, where I
came to the stage where I wish to fix all of the low level region and optimize
just the hydrogen atoms of the QM region. This calculation finished. However,
the next stage was to use this system, and optimize the whole QM region (with
the MM region fixed). These calculations die just before it starts the
high-level calculation on the model system with the following error:
Cartesian Forces: Max 0.059474500 RMS 0.000788502
GradGradGradGradGradGradGradGradGradGradGradGradGradGradGradGradGradGrad
Berny optimization.
Internal Forces: Max 0.047983376 RMS 0.006291829
Search for a local minimum.
Step number 1 out of a maximum of 894
All quantities printed in internal units (Hartrees-Bohrs-Radians)
NRF ne Abs NRFX
Error termination via Lnk1e in /opt/g09/l103.exe
If I reduce the size of the MM region, I get the same error. Also, if I delete
all of the MM region and just run an M06-2X/6-31G(d) calculation (on the QM
part), I have no problems (goes about 35 steps in the optimization in 24 hours).
We are aware that you can split up ONIOM calculations into their parts (to run
separately), which I have tried to generate, yet these don't finish either. I
get the following error:
GradGradGradGradGradGradGradGradGradGradGradGradGradGradGradGradGradGrad
Berny optimization.
Operation on file out of range.
However, this calculation does generate the three inputs for the single-point
calculations on the system before it dies. The high-level calculation on the
model system has all of the MM atoms present, but they appear as:
Bq-#1-0.442200(Iso=1.00782504,Spin=1,GFac=2.792846) -1 -25.988729094663
-0.265707167253 -16.971277852321
Bq-#1--0.631800(Iso=15.99491464) -1 -26.778340617607
-0.824800703903 -17.146345953700
Bq-#1--0.006900(Iso=12) -1 -26.646213612701
-2.047053577460 -16.427388903608
..
If I take this partial output as input for the high-level optimization
calculation on the model system, this calculation will run (but very slowly -
only 2 optimization steps in 24 hours, even though the basis functions are
correct for only the QM atoms being present).
Therefore, my questions are:
Why are my ONIOM calculations dying? Is this a memory or disk problem?
How do I properly calculate the required memory (and disk) for an ONIOM
calculation in Gaussian?
Any help would be greatly appreciated.
Thanks very much for your time,